TK2600 Pulse Voltage Source

TK2600 is a pulsed voltage source device that can output a pulse voltage of up to 2 kV, and its pulse  amplitude, pulse repetition rate and pulse width can be set and adjusted. The rise and fall time of pulse is less than 10 μs, and the step response performance is faster. The communication interface of the device can realize computer program control operation, which is suitable for measuring the response time of current sensor, Roche coil and other equipment, or calibrating pulse shunt, etc.

Features:
Availability:
Quantity:
  • TK2600

  • TUNKIA

TK2600 Pulse Voltage Source

TK2600 Pulse Voltage Source

(Reference only)

1. Summary

TK2600 is a pulsed voltage source device that can output a pulse voltage of up to 2 kV, and its pulse amplitude, pulse repetition rate and pulse width can be set and adjusted. The rise and fall time of pulse is less than 10 μs, and the step response performance is faster. The communication interface of the device can realize computer program control operation, which is suitable for measuring the response time of current sensor, Roche coil and other equipment, or calibrating pulse shunt, etc.


2. Features

Pulse voltage output: 200 V ~ 2 kV

Pulse width: 1 ms ~ 10 ms

Rise time: ≤10 μs

Rising edge falling edge on-time: adjustable within 10 ms ~ 10 s


3. Applications

☆ Measure the Response Time of the Voltage Sensor

TK2600 Pulse Voltage Source Measure the Response Time of the Voltage Sensor

The resulting step voltage signal flows into both the oscilloscope and the voltage sensor under inspection.

Observe the waveforms of the sensor's primary and secondary signals through an oscilloscope.

Using the rise time of the pulse signal as a reference, the response time of the inspected sensor is measured.

TK2600 Pulse Voltage Source Measure the Response Time of the Voltage Sensor


4. Characteristics

☆ Rapid Rise

TK2600 Pulse Voltage Source The output voltage rises quickly

The output voltage rises quickly, and the rise time when the output voltage is 2000 V is better than 10 μs, At this time, the dU/dt rate reaches 200 V/μs, which satisfies the electricity Requirements for signal sources in the relevant testing standards for pressure sensors.




5. Specifications

Pulse Type

Unipolar pulses, rising edges, and falling edges

Output Range

200 V ~ 2 kV

Adjust the Fineness

0.1 V

Single Pulse Width

Adjustable from 1 ms ~ 10 ms

Single Pulse Rise Time

≤10 μs

Rising Edge, Falling Edge

On-Time

Adjustable in the range of 10ms~10s

Voltage Accuracy

± 0.5%* range


6. General Specifications

Power Supply

AC (220±22) V,(50±2) Hz

Maximum Power Consumption

150 VA

Working Environment

Temperature: 15°C ~ 30°C

Humidity: 20% R·H ~ 80%R·H, no condensing

Others: No electromagnetic field interference.

Storage Environment

Temperature: -20°C ~ 70°C

Humidity: <95% R·H, no condensing

Communication Interface

RS232×1



Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap