Welcome To TUNKIA !      Electrical Measurement    Magnetic Measurement
You are here: Home » Products » Single-phase/Three-phase Standard Meter » TH3300 Three-phase Multi-function Standard Meter » TH3300 Three-phase Power Energy Standard Meter

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

TH3300 Three-phase Power Energy Standard Meter

TH3300 is a reference-level three-phase power/energy measurement standard instrument. The instrument uses the world's top devices and advanced measurement self-calibration technologies to ensure that the annual change rate of standard measurement is less than U:20 ppm @ 30 V ~ 480 V; I: 30 ppm @ 50 mA~120 A; P/E: 50 ppm @ (30 V~480 V, 50 mA~120 A).
Features:
Availability:
Quantity:
  • TH3300

  • TUNKIA

TH3300 Three-phase Power Energy Standard Meter

1. Summary

TH3300 is a reference-level three-phase power/energy measurement standard instrument. The instrument uses the world's top devices and advanced measurement self-calibration technologies to ensure that the annual change rate of standard measurement is less than U:20 ppm @ 30 V ~ 480 V; I: 30 ppm @ 50 mA~120 A; P/E: 50 ppm @ (30 V~480 V, 50 mA~120 A). This instrument can meet the test requirements for electric energy measurement under dynamic waveform conditions such as broadband and complex harmonics and under low current conditions, and solves the traceability problem of R46 electric energy measurement.


2. Features

Power/electric energy accuracy class: 0.005.

Voltage measurement range: 1.2 V ~ 528 V.

Current measurement range: 0.2 mA120 A.

Fundamental frequency range: 45 Hz ~ 1 kHz.

The typical phase measurement uncertainty reaches 0.001°;.

Voltage and current support fully automatic range shifting.

The current is input through a pair of binding posts, no need to change wires.

Both voltage and current support 2~127 measurements.

It has the function of comprehensive statistical analysis of the measured power.

Supports phasor diagram, spectrum diagram, trend diagram and other graphic displays.

With standard power pulse input/output function.

Communication interfaces: USB, RS232, LAN.

LCD touch screen.


3. Application

Calibrating Standard Source: Calibrate three-phase voltage sources, current sources, power sources, etc. of class 0.01 and below.

Calibrating Electrical Measuring Instruments: It can be used as a standard meter to match highly stable power source to measure or to calibrate single/three-phase voltmeters, ammeters, power meters, power factor meters, frequency meters, phase meters, transmitters, sensors, etc. below class 0.01.

Calibrating Electric Energy Metering Device: It can be used as a high-level electric energy standard meter to assess three-phase electric energy meter verification devices, standard electric energy meters, charging pile testers, etc. that meet the requirements of the new national standard and the R46 directive at class 0.01 and below.


4. Specifications

4.1 AC Voltage Measurement

Range

Resolution

Measurement Uncertainty at different frequencies 

(Hz)( k = 2)

(ppm*RD + ppm*RG) @(23±5)°C

Temperature Coefficient

ppm*RD/°C

@ (15 ~ 30)°C


45 ≤ F < 80

80 ≤ F < 400

400 ≤ F < 1 k

12 V

1 μV

24 + 16

48 + 32

100 + 60

< 0.5

60 V

1 μV

12 + 8

24 + 16

48 + 32

< 0.4

120 V

10 μV

12 + 8

24 + 16

48 + 32

< 0.4

240 V

10 μV

12 + 8

24 + 16

48 + 32

< 0.4

480 V

10 μV

12 + 8

24 + 16

48 + 32

< 0.4

Note: RD is the reading value, RG is the range value, the same below


4.2 AC Current Measurement

Range

Resolution

Measurement Uncertainty at different frequencies

(Hz) (k = 2)

(ppm*RD + ppm*RG) @(23±5)°C

Temperature Coefficient

ppm*RD/°C

@ (15 ~ 30)°

45 ≤ F < 80

80 ≤ F < 400

400 ≤ F < 1 k

2 mA

0.1 nA

200 + 100

600 + 300

1200 + 600

< 6.0

5 mA

0.1 nA

100 + 50

300 + 150

600 + 300

< 3.0

10 mA

1 nA

50 + 25

150 + 75

300 + 150

< 1.5

20 mA

1 nA

40 + 20

120 + 60

240 + 120

< 0.8

50 mA

1 nA

20 + 10

60 + 30

120 + 60

< 0.4

100 mA

10 nA

20 + 10

60 + 30

120 + 60

< 0.4

200 mA

10 nA

20 + 10

60 + 30

120 + 60

< 0.4

500 mA

10 nA

20 + 10

60 + 30

120 + 60

< 0.4

1 A

0.1 μA

20 + 10

60 + 30

120 + 60

< 0.4

2 A

0.1 μA

20 + 10

60 + 30

120 + 60

< 0.4

5 A

0.1 μA

20 + 10

60 + 30

120 + 60

< 0.4

10 A

1 μA

20 + 10

60 + 30

120 + 60

< 0.4

20 A

1 μA

20 + 10

60 + 30

120 + 60

< 0.4

50 A

1 μA

20 + 10

60 + 30

120 + 60

< 0.4

100 A

10 μA

20 + 10

60 + 30

120 + 60

< 0.4

Measurement range: 0.2 mA120 A

8-digit display, manual/automatic range shifting

Fundamental frequency range: 45 Hz ~ 1 kHz

Long-term stability: 15 ppm/year @ 50 mA120 A


4.3 Frequency/Phase Measurement

Frequency

Range

45.000 000 Hz~1000.000 0 Hz

Minimum Resolution

0.000 001 Hz

Measurement Uncertainty (k=2)

0.001%*RD

Phase

Range

0.000 00°~ 359.999 99°( 50 mA ≤ I ≤ 120 A )

Minimum Resolution

0.000 01°

Measurement Uncertainty (k=2)

0.001°


4.4 Power/Energy Measurement

Measured power

Voltage Range

Current Range

Measurement Uncertainty at different frequencies

(Hz) (k = 2)

45 ≤ F ≤ 80

80 < F ≤ 400

400 < F ≤ 1 k

Active power/

electric energy

Reactive power/

electric energy

Apparent power/

electrical energy

30 V...1000 V

50 mA ≤ I ≤120 A

0.005%*RD

0.015%*RD

0.03%*RD

10 mA ≤ I < 50 mA

0.01%*RD

0.03%*RD

0.06%*RD

2 mA ≤ I < 10 mA

0.02%*RD

0.06%*RD

0.12%*RD

0.2 mA ≤ I < 2 mA

0.05%*FS

0.15%*FS

0.3%*FS

Note ②: FS = voltage range value &times; current range value ③ Active power |cosφ| ≥0.5; ④ Reactive power |cosφ| ≥0.5

Power/electric energy measurement range: combination of AC voltage range and AC current range

Power factor measurement range: -1.000 000 0…0.000 000 0…1.000 000 0

Standard electric energy pulse output: high frequency full scale value corresponds to 120 kHz, low frequency full scale value corresponds to 6 Hz

Standard power pulse input: frequency 200 kHz, voltage: 0…3.3 V…24 V

Long-term stability: 30 ppm/year @ (30V~480V, 50 mA~120 A).


5. General Specification

Power supply: AC (220 ± 22) V, (50 ± 2) Hz; maximum power consumption: 120 VA

Working environment: 18℃~28, 20%85% R H, non-condensing

Storage environment: 0℃~40, < 95% R H, non-condensing

Communication interface: RS232, USB, LAN


6. Accessory List

S/N

Pic

Name

Specification

Quantity

Note

1

Voltage combination test leads

3m/1.6mm2/Φ4 socket-Φ4 socket

4

Standard Accessory

2

Current quick plug test lead

1.5m/25mm2/Φ12 insert→MC quick plug test line

6

Yellow 1

Green 1

Red 1

Black 3

Standard Accessory

3

Reducing plug

MC adapter plug

Red 6

Standard Accessory

4

Power cable

AC 220V、10A

1

Standard Accessory

5

Glass fuse

F3A、250V

3

Standard Accessory

6

Electric energy pulse signal line

1.5 m / BNC male - alligator clip two wires

1

Standard Accessory

7

Signal test leads

1.5 m / BNC Male- BNC Male

1

Standard Accessory

8

Portable case

Waterproof, shockproof, antistatic

1

Standard Accessory



Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap