TD5610 is a modular high-voltage wideband power standard meter. It consists of a V/V converter, an I/V converter and a three-phase wideband standard meter. Under various wiring methods such as three-phase Y/V, it can simultaneously measure multiple electrical parameters in the AC circuit, including: voltage, current, frequency, phase, harmonics, active power, reactive power, apparent power, power factor, active energy, reactive energy, etc. The measurement uncertainty has two specifications of class 0.05 and class 0.02.
Features:
Availability:
Quantity:
  • TD5610

  • TUNKIA

TD5610 Three-Phase High Voltage Wideband Power Standard Meter

TUNKIA TD5610 Three-Phase High Voltage Wideband Power Standard MeterTUNKIA TD5610 Three-Phase High Voltage Wideband Power Standard Meter

1. Summary

TD5610 is a modular high-voltage wideband power standard meter. It consists of a V/V converter, an I/V converter and a three-phase wideband standard meter. Under various wiring methods such as three-phase Y/V, it can simultaneously measure multiple electrical parameters in the AC circuit, including: voltage, current, frequency, phase, harmonics, active power, reactive power, apparent power, power factor, active energy, reactive energy, etc. The measurement uncertainty has two specifications of class 0.05 and class 0.02.

The instrument is widely used, small in size, light in weight, and easy to carry and use on site.


2. Features

Three-phase voltage measurement: 1 kV ~ 10 kV;

Three-phase current measurement: 10 A ~ 1000 A;

F: 45 Hz ~ 1 kHz, harmonic: 45 Hz ~ 5 kHz

Measurement of 2nd ~ 64th harmonics, and display of the content of each harmonic, harmonic histogram and total harmonic distortion

Measurement of multiple electrical parameters in the AC circuit simultaneously under various wiring modes such as three-phase Y/V

Power/electrical energy accuracy: class 0.02 and class 0.05

Oscilloscope, phase diagram display, electrical parameters stability test, trend change curve, data statistical analysis, etc.


3. Application

Calibration of High-Voltage Measuring Devices Under Real Load (Standard Meter Method)

TUNKIA TD5610 Three-Phase High Voltage Wideband Power Standard Meter

Three-phase voltage measurement, range is 1 kV10 kV

Three-phase current direct measurement 10 A1000 A;

Application scenario: suitable for calibrating single-phase/three-phase high-voltage source, high-current source, power source, high-voltage meter, high-current meter, power meter, etc. of class 0.2 and below in the laboratory or on-site.


4. Equipment

Equipment

Specification

Qty

TUNKIA TD5610 Three-Phase High Voltage Wideband Power Standard Meter

I/V Converter (A/B/C Phase)

Through-hole measurement current: three-phase, 10 A ~ 1000 A;

Frequency: 45 Hz ~ 1000 Hz;

Phase: 0.000°~ 359.999°

Harmonic function: 2nd ~ 63rd, total harmonic distortion

1 for each A/B/C phase

TUNKIA TD5610 Three-Phase High Voltage Wideband Power Standard Meter

V/V Converter (A/B/C Phase)

Measuring voltage: three-phase, 1 kV~10 kV;

Frequency: 45 Hz~1000 Hz;

Phase: 0.000°~359.999°

Harmonic function: 2nd~63rd, total harmonic distortion

1

TUNKIA TD5610 Three-Phase High Voltage Wideband Power Standard Meter

Wideband Standard Meter

Synchronously display voltages, frequencies, phases, power/electric energy, power factor, AC harmonics, etc. of multiple channels.

Real-time display of electrical parameter curves U(t), I(t), P(t), E(t), etc.

Communication interface: RS232. It can be used with a computer to establish a comprehensive test system.

1


5. Specifications

5.1 Three-Phase High Voltage V/V Converter

Nominal Input Voltage (kV)

DC

(± ppm)

Maximum AC/DC Difference

(± ppm)

Maximum Phase Shift At Different Frequencies ( ± μrad )

50 Hz

1 kHz

50 Hz

1 kHz

6

100

100

600

150

750

Built-in precision amplifier, voltage is differential output, output impedance: 10Ω@1kHz.


5.2 Three-Phase High Voltage I/V Converter

Nominal Input Current (kA)

DC

(± ppm)

Maximum AC/DC Difference

(± ppm)

Maximum Phase Shift At Different Frequencies ( ± μrad )

50 Hz

1 kHz

50 Hz

1 kHz

1

100

100

600

150

750

Data is transmitted entirely via optical fiber, which has good insulation and strong resistance to external interference.


5.3 Three-Phase Voltage Measurement

Range

Frequency Range

Hz

Measurement Uncertainty ( k=2)

( ppm*RD+ ppm*RG)[1]

Temperature Coefficient

± ppm*RD /

1530

24 Hours

23 ± 1

90 Days

23 ± 5

1 Year

23 ± 5

Class 0.02

Class 0.05

Class 0.02

Class 0.05

Class 0.02

Class 0.05

Class 0.02

Class 0.05

6 kV

(phase voltage)

DC

40+25

80+50

50+32

100+60

60+40

120+80

<15

<30

45100

40+25

80+50

50+32

100+60

60+40

120+80

<15

<30

1001k

200+120

300+200

300+150

400+250

400+200

600+400

<15

<30

10 kV

(line voltage)

DC

40+25

80+50

50+32

100+60

60+40

120+80

<15

<30

45100

40+25

80+50

50+32

100+60

60+40

120+80

<15

<30

1001k

200+120

300+200

300+150

400+250

400+200

600+400

<15

<30

Note [1]: RD is the reading value, RG is the range value, the same below.

The above indicators include the high voltage divider error indicator, manual/automatic shift range, minimum resolution: 1 mV

Measurement range: 1k V ~ 10 kV, measurement method: AC/DC measurement

Measurement bandwidth: fundamental wave: 45 Hz ~ 1 kHz; harmonics: 45 Hz ~ 5 kHz


5.4 Three-Phase Current

Range

Frequency Range

Hz



Measurement Uncertainty ( k=2)

( ppm*RD+ ppm*RG)[1]

Temperature Coefficient

±ppm*RD /

1530

24 Hours

23 ± 1

90 Days

23 ± 5

1 Year

23 ± 5

Class 0.02

Class 0.05

Class 0.02

Class 0.05

Class 0.02

Class 0.05

Class 0.02

Class 0.05

100 A

DC

70+50

120+80

100+60

150+100

120+80

180+120

<15

<30

45100

70+50

120+80

100+60

150+100

120+80

180+120

<15

<30

1001k

300+180

500+300

400+250

600+400

500+300

750+500

<15

<30

200A

DC

70+50

120+80

100+60

150+100

120+80

180+120

<15

<30

45100

70+50

120+80

100+60

150+100

120+80

180+120

<15

<30

1001k

300+180

500+300

400+250

600+400

500+300

750+500

<15

<30

500A

DC

60+30

120+80

80+40

150+100

100+50

180+120

<15

<30

45100

60+30

120+80

80+40

150+100

100+50

180+120

<15

<30

1001k

240+120

500+300

320+160

600+400

400+200

750+500

<15

<30

1000A



DC

60+30

120+80

80+40

150+100

100+50

180+120

<15

<30

45100

60+30

120+80

80+40

150+100

100+50

180+120

<15

<30

1001k

240+120

500+300

320+160

600+400

400+200

750+500

<15

<30

Minimum resolution: 1 mA, the above indicators include I/V converter error indicators, manual/automatic switching range,

Measurement range: 10 A ~ 1000 A, measurement method: DC measurement, AC measurement

Measurement bandwidth: fundamental wave: 45 Hz ~ 1 kHz; harmonics: 45 Hz ~ 5 kHz


5.5 Frequency / Phase / Harmonics

Frequency Adjustment

Adjustment range: 45.000 Hz ~ 1000.000 Hz;

Adjustment fineness: 0.001 Hz;

Measurement uncertainty (k = 2): 0.01 Hz

Phase Adjustment

Adjustment range: 0.000° 359.999°;

Adjustment fineness: 0.005°;

Measurement uncertainty (k = 2): 0.05°


5.6 Three-Phase Power/Energy Measurement

Range

Measurement Uncertainty ( ( k = 2 )

( %*FS)[2]

Class 0.02

Class 0.05

Active power/ energy

|cosφ| ≥ 0.5

0.02

0.05

Reactive power/ energy

|sinφ| ≥ 0.5

0.05

0.1

Apparent power/ energy

0.05

0.1

Power factor

0.05

0.1

Note [2]: FS = voltage range value x current range value

Power factor setting range: -1.000 000…0.000 000…1.000 000

When high-frequency pulse output is used, the full range value corresponds to 60 kHz; when low-frequency pulse output is used, the full range value corresponds to 6 Hz

Electric energy pulse input: frequency 10 kHz, voltage: 03.3 V24 V


6. General Specification

Power Supply

AC (220 ± 22) V, (50 ± 2) Hz

Warm-up Time

30 minutes

Temperature Performance

Operating temperature: 0°C~45°C; Storage temperature: -20°C~70°C

Humidity Performance

Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C

Altitude

Storage humidity: (20%~80%) R H, no condensation

Communication Interface

< 3000 m

Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap