1 Summary
The TM6100 is a high-precision, multi-functional magnetic field measuring instrument equipped with a high-sensitivity, low-drift Hall sensor. It is applied for measuring the magnetic flux density value of a DC (constant) magnetic field or an alternating magnetic field (optional).
2. Features
• Range: 2 mT ~ 3000 m T.
• Accuracy: 0.2% or 0.5%.
• Optional AC measurement mode.
• Unit switch: G, mT, A /m, Oe.
• N/S and +/- polarity display.
• Alarm of exceeding the upper / lower limit.
• Max. hold function.
• One-key clear function.
• Measuring parameter correction.
• Radial and axial Hall probes are optional.
• Digital and analog signal output.
• Optional magnetic shielded cavity.
• Small size, light weight.
3. Application
4. Features
☆ Optional Radial or Axial Hall Probe | ||
Radial Hall Probe | | |
Axial Hall Probe | | |
• Standard configuration is Radial Hall probe, also can choose Axial Hall probe. |
☆ Digital and Analog Signal Output |
|
• Two output modes of digital signal and analog signal. • Directly output the secondary analog signal, and adjust the maximum output voltage. |
☆ One-key Clear Function/ Zero Drift Calibration | |
Zero drift calibration operation | |
Serial Number | Function Description |
| One-key clear function: eliminate the influence of zero drift on the measurement before measuring. |
| Magnetic shielding cavity (optional): • Realize the calibration of the zero drift. • Can completely remove the influence of the earth's magnetic field with the shielding material of high magnetic permeability. • Internal magnetic field <10 -6 T. • Small size, light weight (about 1 kg). |
5. Specifications
Range | 30 mT | 300 mT | 3000 mT ① | |
Resolution | 1 μT | 10 μT | 0.1 mT | |
Measuring Range | 2 mT ~ 3000 mT | |||
Accuracy | 0.5 % | DC: ±(0.5% + 200 μT), AC: ±5%( RMS) ① | ||
0.2 % | DC: ±(0.2% + 200 μT) , AC:±5% (RMS) | |||
Frequency Range | DC, 40Hz ~ 500Hz | |||
Temperature Coefficient | ± 0.1% / K | |||
Zero Drift | ± 0.1 mT /h | |||
Display Digits | 5 | |||
Remark | ① AC mode is a feature selected for the TM6100-B |
6. Ordering Information
7. General Specifications
Power Supply | AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz |
Temperature Performance | Operating temperature: 0°C~50°C Storage temperature: -20°C ~ 70°C |
Humidity Performance | Operating humidity: 40% ~ 80 % R·H, non-condensing Storage humidity: < 80% RH, non-condensing |
Altitude | < 3000 m |
Weight | About 3 kg |
Interface | Hall probe input, RS232 interface |
Dimensions | 225 mm (W) × 170 mm (D) × 115 mm (H) |
8. Probe Selection
Serial number | Picture | Name | Specification | Quantity | Remark |
1 | | TM1100 Hall Probe | radial | 1 | Standard Accessory |
2 | | TM1110 Hall Probe | axial | 1 | Optional |
Note:The users should indicate the probe in the order contract. |
Advanced Multifunction Calibrator Advanced Electrical Reference Standards Electric Vehicle (EV)Charging Facility Tester AC/DC Standard Source /Meter Single-phase/Three-phase Standard Meter Magnetic Parameters Measurement and Calibration Magnetic Material Testing Equipment Electrical Steel Testing Equipment