1 Summary
• Can be connected with a fluxgate magnetometer to measure the low magnetic field in space.
• TM1200 is a uniaxial fluxgate probe and TM1230 is a triaxial probe.
• Can be divided into: micro probe, high-precision standard edition, high-precision low-noise edition, ultra-high-precision standard edition, and ultra-high-precision low-noise edition.
2. Ordering Information
3. Specifications
☆ Micro Fluxgate Probe | |||||
Probe Model | Number of Axes | Range | Noise /√Hz @ 1Hz | Linearity | Frequency Response ( -3dB) |
TM1200-100μT | uniaxial | 100 μT | 1.5nTrms | ≤ 0.5 % | DC to 400 Hz |
TM1200-500μT | uniaxial | 500 μT | 1.5nTrms | ≤ 0.5 % | DC to 400 Hz |
TM1200-1000μT | uniaxial | 1000 μT | 1.5nTrms | ≤ 0.5 % | DC to 400 Hz |
TM1200-2000μT | uniaxial | 2000 μT | 1.5nTrms | ≤ 0.5 % | DC to 400 Hz |
TM1230-100μT | triaxial | 100 μT | 1.5nTrms | ≤ 0.5 % | DC to 400 Hz |
TM1230-500μT | triaxial | 500 μT | 1.5nTrms | ≤ 0.5 % | DC to 400 Hz |
TM1230-1000μT | triaxial | 1000 μT | 1.5nTrms | ≤ 0.5 % | DC to 400 Hz |
TM1230-2000μT | triaxial | 2000 μT | 1.5nTrms | ≤ 0.5 % | DC to 400 Hz |
Note: [1] Uniaxial micro-probe is suitable for TM4100B hand-held uniaxial fluxgate magnetometer. [2] Triaxial micro-probe adapts to TM4300B hand-held triaxial fluxgate magnetometer. |
☆ High Precision Fluxgate Probe | ||||||
Probe Model | Number of Axes | Range | Noise /√Hz @ 1Hz | Linearity | Frequency Response ( -3dB) | OrthogoNality |
TM1200- H -100μT | uniaxial | 100 μT | ≤ 10 pT rms | ≤ 0.01 % | DC to 1kHz | —— |
TM1200- HL -100μT | uniaxial | 100 μT | ≤ 6 pT rms | ≤ 0.01 % | DC to 1kHz | —— |
TM1200- HL -500μT | uniaxial | 500 μT | ≤ 30 pT rms | ≤ 0.02 % | DC to 1kHz | —— |
TM1200- HL -1000μT | uniaxial | 1000 μT | ≤ 50 pT rms | ≤ 0.02 % | DC to 1kHz | —— |
TM1230- H -100μT | triaxial | 100 μT | ≤ 10 pT rms | ≤ 0.01 % | DC to 1kHz | ≤ ±0.2° |
TM1230- HL -100μT | triaxial | 100 μT | ≤ 6 pT rms | ≤ 0.01 % | DC to 1kHz | ≤ ±0.2° |
TM1230- HL -500μT | triaxial | 500 μT | ≤ 30 pT rms | ≤ 0.02 % | DC to 1kHz | ≤ ±0.2° |
TM1230- HL -1000μT | triaxial | 1000 μT | ≤ 50 pT rms | ≤ 0.02 % | DC to 1kHz | ≤ ±0.2° |
Note: [3] High-precision uniaxial/triaxial probes are suitable for TM4300B fluxgate magnetometer. |
☆ Ultra-high Precision Fluxgate Probe | ||||||
Probe Model | Number of Axes | Range | Noise /√Hz @ 1Hz | Linearity | Frequency Response ( -3dB) | OrthogoNality |
TM1200-S-100μT | uniaxial | 100 μT | 10 ~ 20 pT rms | ≤ 0.01 % | DC to 3kHz | —— |
TM1200-S-500μT | uniaxial | 500 μT | 10 ~ 20 pT rms | ≤ 0.01 % | DC to 3kHz | —— |
TM1200-S-1000μT | uniaxial | 1000 μT | 10 ~ 20 pT rms | ≤ 0.01 % | DC to 3kHz | —— |
TM1230-S-100μT | triaxial | 100 μT | 6 ~ 10 pT rms | < 0.0015 % | DC to 3kHz | ≤ ±0.1° |
TM1230-S-500μT | triaxial | 500 μT | 6 ~ 10 pT rms | < 0.0015 % | DC to 3kHz | ≤ ±0.1° |
TM1230-S-1000μT | triaxial | 1000 μT | 6 ~ 10 pT rms | < 0.0015 % | DC to 3kHz | ≤ ±0.1° |
TM1230-SL-100μT | triaxial | 100 μT | ≤ 6 pT rms | < 0.0015 % | DC to 3kHz | ≤ ±0.1° |
Note: [4] Ultra-high-precision uniaxial/triaxial probes are suitable for TM4300B fluxgate magnetometer. |
☆ Probe Dimensions | ||
Probe Type | Number of Axes | Size (length, width and height ) |
Micro Fluxgate Probe | uniaxial | 20mm 13mm 6.3mm |
triaxial | 20mm 14mm 12mm | |
High Precision Fluxgate Probe | uniaxial | 110mm 30mm 30mm |
triaxial | 120mm 30mm 30mm | |
Ultra High Precision Fluxgate Probe | uniaxial | 100mm 44mm 30mm |
triaxial | 225mm 32mm 32mm |
Advanced Multifunction Calibrator Advanced Electrical Reference Standards Electric Vehicle (EV)Charging Facility Tester AC/DC Standard Source /Meter Single-phase/Three-phase Standard Meter Magnetic Parameters Measurement and Calibration Magnetic Material Testing Equipment Electrical Steel Testing Equipment