TM4830B Fluxgate Magnetometer

The TM4830B is a portable, multi-functional weak field measuring instrument, which can be matched with fluxgate sensors of various specifications and measurement ranges, including single-axis and three-axis fluxgate sensors, which can measure the weak magnetic field.
Features:
Availability:
Quantity:
  • TM4830B

  • TUNKIA

TM4830B Fluxgate Magnetometer

TM4830B Fluxgate Magnetometer

1 Summary

The TM4830B is a portable, multi-functional weak field measuring instrument, which can be matched with fluxgate sensors of various specifications and measurement ranges, including single-axis and three-axis fluxgate sensors, which can measure the weak magnetic field.


2. Features

• Range: 0~ 2000 μT, various of probes are optional.

• Measure XYZ component value, vector value and angle.

• Mainframe voltage measurement up to 0.005%.

• 0.0015 % for the ultra-high precision version.

• The noise of the low noise version is typically < 6 pTrms /√Hz.

• Unit switch: μT, mG .

• Switch 6 / 7 / 8-digits display.

• AC or DC mode, and AC frequency display.

• Relative measurement mode, offset value (Offset) input.

• Alarm function of exceeding the upper / lower limit.

• Max. / min. hold function.

• Data statistical analysis and trend chart display.

• The integration period (refresh rate): 0.5s to 100s.

• (ultra-) High-accuracy probes support temperature compensation.

• USB, LAN, RS 232 interface.

• LCD touch screen.


3. Application

• Measuring low magnetic field.

• Geological prospecting.

• Fragmentation processing, security check.

• Fault location, research experiment.

• Magnetic shielding evaluation.

• Calibrating low magnetic field sources.

• Detecting magnetic resonance meter.

• Detecting electron microscope.

• Detecting Magnetic field drift.



4. Specifications

4.1 Main Unit (Voltage Measurement)

Range

0 ~ ± 10V

Accuracy

±(ppm of reading + ppm of range) [1]

DC

0.003 % + 0.002 %

20 Hz~ 45Hz _

0.06 % + 0.04 %

45 Hz~1k Hz _

0.012 % + 0.008 %

DC Linearity

0.002 %

Display digits

8 digits display

Probe Supply Voltage

± 15V

Data Refresh Time

0.5 s ~ 100 s adjustable

Remark

Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).


4.2 Fluxgate Probe

☆ Miniature Fluxgate Probe

Probe Model

Number of Axes

Range

Noise

/√Hz @ 1Hz

Linearity

Frequency Response

( -3dB)

TM1200-100μT

single-axis

100 μT

1.5nTrms

≤ 0.5 %

DC to 400 Hz

TM1200-500μT

single-axis

500 μT

1.5nTrms

≤ 0.5 %

DC to 400 Hz

TM1200-1000μT

single-axis

1000 μT

1.5nTrms

≤ 0.5 %

DC to 400 Hz

TM1200-2000μT

single-axis

2000 μT

1.5nTrms

≤ 0.5 %

DC to 400 Hz

TM1230-100μT

three-axis

100 μT

1.5nTrms

≤ 0.5 %

DC to 400 Hz

TM1230-500μT

three-axis

500 μT

1.5nTrms

≤ 0.5 %

DC to 400 Hz

TM1230-1000μT

three-axis

1000 μT

1.5nTrms

≤ 0.5 %

DC to 400 Hz

TM1230-2000μT

three-axis

2000 μT

1.5nTrms

≤ 0.5 %

DC to 400 Hz


☆ High Precision Fluxgate Probe

Probe Model

Number of Axes

Range

Noise

/√Hz @ 1Hz

Linearity

Frequency Response

( -3dB)

Orthogonality

TM1200- H -100μT

single-axis

100 μT

≤ 10pT rms

≤ 0.01 %

DC to 1kHz

——

TM1200- HL -100μT

single-axis

100 μT

≤ 6pT rms

≤ 0.01 %

DC to 1kHz

——

TM1200- HL -500μT

single-axis

500 μT

≤ 30pT rms

≤ 0.02 %

DC to 1kHz

——

TM1200- HL -1000μT

single-axis

1000 μT

≤ 50pT rms

≤ 0.02 %

DC to 1kHz

——

TM1230- H -100μT

three-axis

100 μT

≤ 10pT rms

≤ 0.01 %

DC to 1kHz

≤ ±0.2°

TM1230- HL -100μT

three-axis

100 μT

≤ 6pT rms

≤ 0.01 %

DC to 1kHz

≤ ±0.2°

TM1230- HL -500μT

three-axis

500 μT

≤ 30pT rms

≤ 0.02 %

DC to 1kHz

≤ ±0.2°

TM1230- HL -1000μT

three-axis

1000 μT

≤ 50pT rms

≤ 0.02 %

DC to 1kHz

≤ ±0.2°


☆ Ultra-high Precision Fluxgate Probe

Probe Model

Number of Axes

Range

Noise

/√Hz @ 1Hz

Linearity

Frequency Response

( -3dB)

Orthogonality

TM1200-S-100μT

single-axis

100 μT

10 ~ 20pT rms

≤ 0.01 %

DC to 3kHz

——

TM1200-S-500μT

single-axis

500 μT

10 ~ 20pT rms

≤ 0.01 %

DC to 3kHz

——

TM1200-S-1000μT

single-axis

1000 μT

10 ~ 20pT rms

≤ 0.01 %

DC to 3kHz

——

TM1230-S-100μT

three-axis

100 μT

6 ~ 10pT rms

< 0.0015 %

DC to 3kHz

≤ ±0.1°

TM1230-S-500μT

three-axis

500 μT

6 ~ 10pT rms

< 0.0015 %

DC to 3kHz

≤ ±0.1°

TM1230-S-1000μT

three-axis

1000 μT

6 ~ 10pT rms

< 0.0015 %

DC to 3kHz

≤ ±0.1°

TM1230-SL-100μT

three-axis

100 μT

≤6pT rms

< 0.0015 %

DC to 3kHz

≤ ±0.1°

Note: [1] The user should indicate it in the order contract or technical agreement.

[2] The corresponding probe is selected according to the measurement of range.


4.3 Magnetic Field Measurement

Range

±100 μT

±500 μT

±1000 μT

±2000 μT

Resolution

0.01 nT

0.01 nT

0.1 nT

0.1 nT

Accuracy

±(ppm of reading + ppm of range) [1]

Ultra High Precision Version

0.12 % + 0.08 %

——

High Precision Version

0.3 % + 0.2 %

——

Micro Version

0.6% + 0.4

Remark

The accuracy is the combination of the host and probe.


5. General Specifications

Power Supply

AC ( 220 ± 22 ) V , ( 50 ± 2 ) Hz

Temperature Performance

Working temperature: 0°C~40°C;

Storage temperature: -20°C ~ 70°C

Humidity Performance

Working humidity: 40% ~ 85% R·H without condensation

Storage humidity: < 90% R H, no condensation

Weight

About. 5 kg

Interface

Fluxgate probe, USB, RS232, analog output, network port

Dimensions

190mm (W) × 300 mm (D) × 200 mm (H)


6. Ordering Information

TM4830B Fluxgate Magnetometer

Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap