Welcome To TUNKIA !      Electrical Measurement    Magnetic Measurement
You are here: Home » Products » Advanced Electrical Reference Standards » TH0690 Current Transducer Integrated Measurement Analyzer » TH0690 Current Transducer Integrated Measurement Analyzer

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

TH0690 Current Transducer Integrated Measurement Analyzer

TH0690 is an intelligent instrument designed for the comprehensive performance evaluation of current transformers. It can accurately detect the electrical characteristics such as the ratio error (k) and phase displacement (δ) of I/I and I/V type current transformers. It can also measures the AC magnetic characteristics of the transformer core. It solves the complex problem of the interrelationship between magnetic performance and electrical performance in the design process of transformers, providing the most complete means for the detection of current transformers.
Availability:
Quantity:
  • TH0690

  • TUNKIA

TH0690 Current Transducer Integrated Measurement Analyzer

TH0690 Current Transducer Integrated Measurement Analyzer

1. Summary

TH0690 is an intelligent instrument dedicated to the comprehensive performance evaluation of current transducers. It can accurately test the electrical characteristics such as ratio error (k) and phase displacement (δ) of I/I and I/V current transformers, and can also measure the AC magnetic characteristics of the transformer core. It solves the problem of complex calculation of the relationship between magnetic properties and electrical properties in the process of transducers design, and provides the most complete means for the analysis and measurement of current transformers.


2. Feature

  • AC Power Output/Measurement Accuracy: Class 0.005

  • Working Frequency Range: 45 Hz~65 Hz.

  • Support multi-frequency point measurement of ratio error (k) and phase displacement (δ)

  • Draw frequency or current characteristic curve with the software。

  • Support various magnetic characteristic parameter measurement and curve drawing.

  • With automatic demagnetization function, it can evaluate the magnetic resistance of the transformer.

  • Special Test Software (optional)


3. Application

  • Current transformer ratio error (k) and phase displacement (δ) calibration.

  • Magnetic performance testing of finished transformers and semi-finished iron cores.

  • Current transformer quality inspection, design verification, iron core pairing.

  • Ratio error (k) and phase displacement (δ) measurement of the current measurement circuit.

  • Anti-magnetic evaluation of current transformers.


☆ Current transformer ratio error and phase displacement calibration.

TH0690 Current Transducer Integrated Measurement Analyzer Current transformer ratio error and phase displacement calibration

Measure and calibrate the ratio error and phase displacement of the current transformer.

Draw the frequency characteristic curve k(F), δ(F),current characteristic curve k(I), δ(I).

☆ Measuring the magnetic properties of core semi-finished products.

TH0690 Current Transducer Integrated Measurement Analyzer Measuring the magnetic properties of core semi-finished products.

It can measure the magnetic properties of finished transformers and semi-finished iron cores.

Parameter Measurement: μi, μm, Hc, Br, Bs, μa, Bm, Hm, δ etc.

4. Specifications

4.1 ACI Output/ I1

Current Range

Short-term Stability

(%/min)

Measurement Uncertainty

(k=2, ppm*RD+ppm*RG)

Maximum Load Voltage(V)

Distortion

(%)

24 h

(23±1)°C

90 days

(23±5)°C

1 year

(23±5)°C

2 mA

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

5 mA

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

10 mA

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

20 mA

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

50 mA

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

100 mA

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

200 mA

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

500 mA

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

1 A

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

2 A

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

5 A

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

10 A

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

20 A

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

50 A

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

100 A

0.003

20 + 20

25 + 20

30 + 20

1.2

< 0.2

Note: ① RD is the reading value, RG is the range value, the same below.

  • ACI Output:200 μA~120 A,7-digit display.

  • Frequency range: 45 Hz~65 Hz; Adjustment Fineness: 0.0001 Hz; Measurement Uncertainty: 0.001 Hz

  • Protection Function: short circuit protection, overload protection.


4.2 ACV Measurement /U2 and ACI Measurement/I2

AC

Range

Resolution

Measurement Uncertainty

(k=2, ppm*RD +ppm*RG)

24 h

(23±1)°C

90 days

(23±5)°C

1 year

(23±5)°C

ACV/U2

20 mV

10 nV

40 + 40

50 + 40

60 + 40

50 mV

10 nV

20 + 20

25 + 20

30 + 20

100 mV

100 nV

20 + 20

25 + 20

30 + 20

200 mV

100 nV

20 + 20

25 + 20

30 + 20

500 mV

100 nV

20 + 20

25 + 20

30 + 20

1 V

1 μV

20 + 20

25 + 20

30 + 20

2 V

1 μV

20 + 20

25 + 20

30 + 20

5 V

1 μV

20 + 20

25 + 20

30 + 20

ACI/I2

200 μA

0.1 nA

20 + 20

25 + 20

30 + 20

500 μA

0.1 nA

20 + 20

25 + 20

30 + 20

1 mA

1 nA

20 + 20

25 + 20

30 + 20

2 mA

1 nA

20 + 20

25 + 20

30 + 20

5 mA

1 nA

20 + 20

25 + 20

30 + 20

10 mA

10 nA

20 + 20

25 + 20

30 + 20

20 mA

10 nA

20 + 20

25 + 20

30 + 20

50 mA

10 nA

20 + 20

25 + 20

30 + 20

100 mA

100 nA

20 + 20

25 + 20

30 + 20

  • U2 Measurement Range: 2 mV~5.5 V,7-digit display.

  • I2 Measurement Range: 20 μA~110 mA,7-digit display.

  • Harmonic Measurement: 2nd to 63rd.


4.3 Ratio Error (k) and Phase Displacement (δ) Measurement

Ratio Error

Measurement Range

Current transformer input current like I1

Current transformer output current like I2

Measurement Uncertainty (k=2)

0.01% @ 45 Hz ~ 65 Hz

Phase Displacement

Measurement Range

0.000°~359.999°

Measurement Uncertainty (k=2)

0.001° @ 45 Hz~65 Hz


4.4 Measurement of Magnetic Parameters of Current Transformer Iron Core

Measured Parameters

Measurement Uncertainty

(k=2)

Measurement Repeatability

μi

1.5%

4.0%

μm

1.0%

2.0%

Hc

0.5%

1.0%

Br

0.3%

1.0%

Bs

0.3%

1.0%

μa

1.0%

3.0%

Bm

0.5%

1.0%

Hm

1.0%

2.0%

δ

1.5%

5.0%

Hc

1.0%

3.0%

Br

1.0%

3.0%

μ’

1.0%

3.0%

μ′′

1.0%

3.0%

μL

1.0%

3.0%

Note: The iron core should be demagnetized before the test, and the parameters of the iron core should be input as required. The measurement temperature T: (23±5)°C.



Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap