TH0410 High Frequency Coaxial Shunt

TH0410 is a set of nine precision AC/DC shunts of different ranges that convert a nominal input current of 20 mA ~ 10 A to 1 V Small voltage, easy to access voltage high-speed sampling system or high-precision data meter, to achieve wideband or complex waveform current measurement, or used to calibrate wideband current sources, transformers, sensors, etc.
Availability:
Quantity:
  • TH0410

  • TUNKIA

TH0410 High Frequency Coaxial Shunt

TH0410 High Frequency Coaxial Shunt

1. Summary

TH0410 is a set of nine precision AC/DC shunts of different ranges that convert a nominal input current of 20 mA ~ 10 A to 1V Small voltage, easy to access voltage high-speed sampling system or high-precision data meter, to achieve wideband or complex waveform current measurement, or used to calibrate wideband current sources, transformers, sensors, etc.


2. Features

• Operating frequency: DC ~ 1 MHz

• AC and DC difference: ≤ 30 ppm @53Hz

• Optimal phase displacement: 5 μrad

• The nominal output voltage is 1 V (other voltage values can be customized).

• The typical annual variation is typically 5 ppm and the maximum is 18 ppm.

• The 1 mA, 10 mA versions mate buffers to reduce output impedance.


3. Applications

☆  Build Wideband Current Measurement System

TH0410 High Frequency Coaxial Shunt Build Wideband Current Measurement System

TH0410 can be used with wideband current source, wideband standard voltmeter (such as TH2000 vector voltage analyzer), etc. to form a wideband current measurement system, which is used to measure wideband current signals, calibrate wideband current sources, wideband ammeters, etc.


☆ Set up wideband power precision measurement system

TH0410 High Frequency Coaxial Shunt Set up wideband power precision measurement system

TH0410 can be used with high-frequency V/V conversion standard and TH2000 vector voltage analyzer to form a wideband power/energy precision measurement system for measuring wideband power/ Power signal, calibration of wideband power source, wideband power meter, power analyzer and other equipment.


☆ Build a wideband instrument transformer / sensor measurement system

TH0410 High Frequency Coaxial Shunt Build a wideband instrument transformer / sensor measurement system

For the calibration of the transformer or sensor under test with a nominal current of ≤ 10A, TH0410 can be used directly as the standard device, with a widebandconstant current source and a wideband sensor tester ( vector voltage analyzer), etc. to form a wideband transformer/sensor measurement system.


☆ Build a wideband transformer/sensor calibration system

TH0410 High Frequency Coaxial Shunt Build a wideband transformer/sensor calibration system

For calibration of transformers or sensors with nominal currents greater than 10 A, TH0410 is used as a secondary signal I/V converter for standard and tested equipment, with wideband constant current source, wideband sensor testers (vector voltage analyzers), etc. form wideband transformers/sensor measurement systems.


☆ Set up sensor bandwidth calibration system

TH0410 High Frequency Coaxial Shunt Set up sensor bandwidth calibration system

TH0410 can be used with wideband standard voltmeters (such as TH2000 vector voltage analyzer) to form a sensor bandwidth calibration system.


4. Specifications

4.1 Resistance

Specifications

Nominal resistance

( Z )

Initial deviation [1]

( ±mH/Z )

@ (23±1)°C

Annual stability

( ±mH/Z )

Temperature coefficient

( ±ppm/K )

Power factor [2]

( ±ppm/rated power )

TH0410-20mA

50

50

18

2.5

1

TH0410-50mA

20

50

18

2.5

1

TH0410-100mA

10

50

18

2.5

2

TH0410-200mA

5

50

18

2.5

4

TH0410-500mA

2

50

18

2.5

12

TH0410-1A

1

50

18

4.0

25

TH0410-2A

500 m

50

18

4.0

25

TH0410-5A

200 m

50

18

4.0

30

TH0410-10A

100 m

50

18

4.0

60

Note [1]: The initial deviation is the maximum offset of the resistance value under DC conditions, usually the manufacturer's factory warranty; Higher accuracy can be customized according to user requirements, such as 20 μΩ/Ω.

Note [2]: When measuring DCI with a coaxial shunt, the resistance value changes due to the heat generation of the resistor itself at different input currents, resulting in an error, and the calculation formula is:

calculation formula


4.2 Current measurement

Specifications

Primary nominal current (A)

Secondary nominal

Voltage (V)

AC/DC difference [3] (±ppm)

Maximum operating

Current (A)

Instantaneous current

(A, <5 s)

50 Hz

1 kHz

1 MHz

TH0410-20mA

20 m

1

20

25

50

40m

250m

TH0410-50mA

50 m

1

20

25

50

100m

500m

TH0410-100mA

100 m

1

20

25

25

200m

1.5

TH0410-200mA

200 m

1

20

25

25

500m

2

TH0410-500mA

500 m

1

20

25

25

1

3

TH0410-1A

1

1

20

25

30

1.5

4

TH0410-2A

2

1

20

30

50

2.5

6

TH0410-5A

5

1

20

30

80

5.5

20

TH0410-10A

10

1

20

30

100

11

30

Note [3]: The measured value of AC current should be calculated according to the following formula, and the unit of AC and DC difference is ppm:

 AC current should be calculated


4.3 Phase displacement

Specifications

Phase displacement (±μrad)

53 Hz

400 Hz

1 kHz

10 kHz

50 kHz

100 kHz

1 MHz

TH0410-20mA

5

5

10

100

400

800

800

TH0410-50mA

5

5

10

100

400

800

800

TH0410-100mA

5

5

10

60

300

500

500

TH0410-200mA

5

5

10

60

300

500

500

TH0410-500mA

5

5

10

60

300

500

500

TH0410-1A

5

5

10

60

300

500

500

TH0410-2A

10

10

15

110

500

1000

1000

TH0410-5A

10

15

25

200

1000

2000

2000

TH0410-10A

10

20

40

300

1500

3000

3000


5. General Specifications

Power supply

——

Temperature performance

Working temperature: 13°C~33°C;

Calibration temperature: 18°C~28°C;

Storage temperature: 5°C ~ 45°C

Note: When stored in harsh temperature environments, it may cause a temporary change in the resistance value and return to the original resistance value within the next 30 days.

Humidity performance

Operating humidity: < 50% R·H

Storage humidity: (15%~80%) R·H, no condensing

Altitude

< 3000 m

Connection method

Input connection: Type-N type female plug;

Output connection: Type-N type female plug.

Type-N type female plug



Specifications

Size( mm ) ( W×D×H )

( without terminal blocks )

Quality

( kg )

Dimensional drawing

TH0410-2 0 mA

TH0410-5 0 mA

TH0410-100mA

65 x 68 x 68

0.1

TH0410 High Frequency Coaxial Shunt Dimensional drawing

TH0410-200mA

TH0410-500mA

TH0410-1A

TH0410-2A

82 x 94 x 94

0.2

TH0410 High Frequency Coaxial ShuntDimensional drawing2

TH0410-5A TH0410-10A

154 x 205 x 205

1

TH0410 High Frequency Coaxial ShuntDimensional drawing


6. Ordering Information





TH0410 High Frequency Coaxial Shunt Ordering Information



Model

Nominal current

TH0410-20mA

20 mA

TH0410-50mA

50 mA

TH0410-100mA

1,00 mA

TH0410-200mA

200 mA

TH0410-500mA

500 mA

TH0410-1A

1 A

TH0410-2A

2 A

TH0410-5A

5 A

TH0410-10A

10 A




Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap