TS2500 Magnetic Properties Measuring
System for Electrical Steel Cores
*Above picture is only for reference, subject to actual delivery
TS2500 consists of excitation and measurement host, automatic measurement software. It’s specially used to testing magnetic properties of motor laminated stator or electrical steel core.It can automatically measure the iron loss and other magnetic parameters of the motor stator core or other types of electrical steel core within a certain frequency range.
Electrical parameters calibration function.
Testing frequency: 50Hz or 60Hz (400Hz、1kHz is optional).
Testing mode: setting H to measure B or setting B to measure Ps.
Testing in full frequency range with good accuracy and repeatability.
Automatically testing with professional software.
Automatically calculating magnetic parameters and curves.
Complete curves drawing and data management functions.
Modular design, easy to upgrade or maintenance.
Multi-strand wire is customizable to simplify winding process.
Output | Max. Power | 10 kVA (Optional) |
Frequency | 50 Hz / 60 Hz…400 Hz…1 kHz (Optional) | |
Protect | Over current, Overload, Over temperature, Short circuit protection | |
Measurement | Uncertainty of U and I (k=2) | 0.1%*RG ① |
Uncertainty of Power (k=2) | 0.3%*FS ② |
Note: ① RG is the range value, ② FS = Voltage range value × Current range value.
Note: The above indicators are typical cases, and the actual parameters should be planned in detail according to the samples tested by users.
Typical Frequency Point | Magnetic Parameters | Typical Test Point⑤ | Uncertainty (k=2) | Repeatability |
50Hz / 60Hz | Ps | P0.5 ②... P1.5 | 2.0% | 0.5% |
400 Hz | Ps | P0.5 ②... P1.5 | 2.5% | 1.0% |
1 kHz | Ps | P0.5 ②... P1.0 | 3.0% | 1.5% |
Note ③: Test conditions : ( 23 ± 5 )℃, demagnetize core before testing.
Note ④: Don’t move the measured core and coils, repeated measurements for serval times, and calculate measurement repeatability.
Note ⑤: The test points are only reference. Actual performance of the measured core due to the material properties, weight, testing frequency, current, power load capacity.
Note ⑥: P1.0 refers to the specific total loss value when B=1.0T, and so on.
5. General Specifications
Power Supply | AC ( 380 ± 38 ) V,( 50 ± 2 ) Hz |
Temperature Performance | Operating Temperature:( 23 ± 5 )℃; Storage Temperature:-20°C~70°C |
Humidity Performance | Operating Storage:40%~80% R·H,non-condensing Storage Humidity:< 80% R·H,non-condensing |
6. Ordering Information
Advanced Multifunction Calibrator Advanced Electrical Reference Standards Electric Vehicle (EV)Charging Facility Tester AC/DC Standard Source /Meter Single-phase/Three-phase Standard Meter Magnetic Parameters Measurement and Calibration Magnetic Material Testing Equipment Electrical Steel Testing Equipment