1. Summary
The TK4860 series is a series of high-efficiency testing instruments specially developed to address the problems of complex wiring, difficult handling, low testing efficiency, and high cost during the on-site testing of AC charging stations.
TK4860E is one of the all-in-one portable instruments specially designed for on-site metrological testing of AC charging stations for electric vehicles. It is available in single-phase and three-phase options. Among them, the single-phase TK4860E-S instrument integrates a single-phase 8kW load internally. In addition to the single-phase 8kW load integrated inside the single-phase TK4860E-T instrument, it can also be connected to an external high-power AC resistive load or electric vehicle.
During testing, the charging stations can be calibrated directly according to the preset calibration points. The instrument is operated through a wireless tablet. A single device can complete the single-phase charging stations working error and clock time error test. It is also easy to carry and can be easily completed by a single person for on-site testing of charging stations.
2. Features
• The single-phase TK4860E-S has a built-in 8 kW single-phase AC load and does need to carry additional loads for testing to complete the testing of single-phase chargers.
• In addition to the built-in 8 kW single-phase AC load, the three-phase TK4860E-T can also be cascaded with three-phase 45kW resistive loads or electric vehicles, and can complete the testing of single-phase chargers or three-phase chargers.
• Wide dynamic range measurement technology avoids measurement risks caused by fluctuations in charging stations output.
• The ms-level energy refresh speed reduces the error caused by the asynchronous accumulation of electric energy between charging stations and standard instruments, and improves the measurement accuracy of accumulated electric energy.
• Integration: A single device integrates the power measurement module, charging control guidance circuit, 8 kW single-phase AC load, etc. A single device can complete the working error testing of the AC charger, effectively improving efficiency;
• Fixed power: The system can preset the charging power and automatically control the start and stop of the charger.
• Waveform distortion measurement: It has the function of measuring voltage and current waveform distortion.
• Clock verification function: real-time clock display, which can complete the clock time error test of the charger.
• Temperature probe: A wired temperature probe is standard, which can complete on-site temperature measurement.
• Bluetooth temperature and humidity meter (optional accessory): An optional Bluetooth temperature and humidity meter can be connected to a tablet via Bluetooth to complete on-site temperature and humidity measurements and automatically record data.
• Traceable calibration: with dedicated calibration terminals to facilitate instrument calibration.
• Wireless tablet operation allows you to save on-site information by taking photos and complete automatic testing.
• With its own display screen, the working error test can be completed directly on the lower computer display screen.
• High reliability: The load uses high-reliability alloy resistors, which support 8 hours of continuous full-load operation. The equipment will not experience abnormalities such as overheating, and the measurement accuracy can be ensured.
• Safety protection: equipped with overvoltage protection, overcurrent protection, abnormal wind speed protection, and emergency stop switch;
• Portable: By fixing the calibration points and loads, the weight and volume of the equipment are minimized. It is also equipped with special retractable pull rods and rollers, so a single person can easily complete on-site inspections.
• Power supply mode: supports three modes: mains power supply, gun head power supply and built-in lithium battery power supply.
3. Application
4. Testing Items
• Working error: A single device can complete the working error test of charger.
• Clock verification: It has time synchronization function, real-time clock display, and clock time error test of the charger.
5. Appearance
Note: The above picture is a schematic diagram of TK4860E-S. TK4860E-T also has an additional load expansion interface.
1. Summary
The TK4860 series is a series of high-efficiency testing instruments specially developed to address the problems of complex wiring, difficult handling, low testing efficiency, and high cost during the on-site testing of AC charging stations.
TK4860E is one of the all-in-one portable instruments specially designed for on-site metrological testing of AC charging stations for electric vehicles. It is available in single-phase and three-phase options. Among them, the single-phase TK4860E-S instrument integrates a single-phase 8kW load internally. In addition to the single-phase 8kW load integrated inside the single-phase TK4860E-T instrument, it can also be connected to an external high-power AC resistive load or electric vehicle.
During testing, the charging stations can be calibrated directly according to the preset calibration points. The instrument is operated through a wireless tablet. A single device can complete the single-phase charging stations working error and clock time error test. It is also easy to carry and can be easily completed by a single person for on-site testing of charging stations.
2. Features
• The single-phase TK4860E-S has a built-in 8 kW single-phase AC load and does need to carry additional loads for testing to complete the testing of single-phase chargers.
• In addition to the built-in 8 kW single-phase AC load, the three-phase TK4860E-T can also be cascaded with three-phase 45kW resistive loads or electric vehicles, and can complete the testing of single-phase chargers or three-phase chargers.
• Wide dynamic range measurement technology avoids measurement risks caused by fluctuations in charging stations output.
• The ms-level energy refresh speed reduces the error caused by the asynchronous accumulation of electric energy between charging stations and standard instruments, and improves the measurement accuracy of accumulated electric energy.
• Integration: A single device integrates the power measurement module, charging control guidance circuit, 8 kW single-phase AC load, etc. A single device can complete the working error testing of the AC charger, effectively improving efficiency;
• Fixed power: The system can preset the charging power and automatically control the start and stop of the charger.
• Waveform distortion measurement: It has the function of measuring voltage and current waveform distortion.
• Clock verification function: real-time clock display, which can complete the clock time error test of the charger.
• Temperature probe: A wired temperature probe is standard, which can complete on-site temperature measurement.
• Bluetooth temperature and humidity meter (optional accessory): An optional Bluetooth temperature and humidity meter can be connected to a tablet via Bluetooth to complete on-site temperature and humidity measurements and automatically record data.
• Traceable calibration: with dedicated calibration terminals to facilitate instrument calibration.
• Wireless tablet operation allows you to save on-site information by taking photos and complete automatic testing.
• With its own display screen, the working error test can be completed directly on the lower computer display screen.
• High reliability: The load uses high-reliability alloy resistors, which support 8 hours of continuous full-load operation. The equipment will not experience abnormalities such as overheating, and the measurement accuracy can be ensured.
• Safety protection: equipped with overvoltage protection, overcurrent protection, abnormal wind speed protection, and emergency stop switch;
• Portable: By fixing the calibration points and loads, the weight and volume of the equipment are minimized. It is also equipped with special retractable pull rods and rollers, so a single person can easily complete on-site inspections.
• Power supply mode: supports three modes: mains power supply, gun head power supply and built-in lithium battery power supply.
3. Application
4. Testing Items
• Working error: A single device can complete the working error test of charger.
• Clock verification: It has time synchronization function, real-time clock display, and clock time error test of the charger.
5. Appearance
Note: The above picture is a schematic diagram of TK4860E-S. TK4860E-T also has an additional load expansion interface.
6. Specification
6.1 TK4860E-S (Single-Phase)
6.1.1 Single-Phase Voltage/Current
Measurement | Accuracy Class | ||
Class 0.05 | Class 0.1 | ||
Voltage | Range | 220 V | 220 V |
Measurement Range | 220 V ± 20% | 220 V ± 20% | |
Current | Range | 30 A | 30 A |
Measurement Range | 0.1 A~36 A | 0.1 A~36 A | |
Waveform Distortion | Measurement Uncertainty (k=2) | 0.5% | 0.5% |
6.1.2 Single Phase Power/Energy Measurement
Voltage Range | Current Range | Power Factor | Measurement Uncertainty (k=2) | |
Class 0.05 | Class 0.1 | |||
220 V ± 20% | 0.1 A~36 A | 0.8L~1~0.8C | 0.05%*RD | 0.1%*RD |
6.1.3 Load
Load | Load Power | Single phase 8kW, does not support load expansion |
Heat Dissipation | Forced air cooling | |
Protection | Overvoltage protection, overcurrent protection, abnormal wind speed protection |
6.2 TK4860E-T (Three-phase)
6.2.1 Three-Phase Voltage/Current
Measurement | Accuracy Class | ||
Class 0.05 | Class 0.1 | ||
Three-Phase Voltage | Range | 220 V | 220 V |
Measurement Range | 220 V ± 20% (phase voltage) | 220 V ± 20% (phase voltage) | |
Three-Phase Current | Range | 60 A | 60 A |
Measurement Range | 0.1 A~72 A | 0.1 A~72 A | |
Waveform Distortion | Measurement Uncertainty (k=2) | 0.5% | 0.5% |
6.2.2 Three-Phase Power/Energy Measurement
Voltage Range | Current Range | Power Factor | Measurement Uncertainty (k=2) | |
Class 0.05 | Class 0.05 | |||
220 V ± 20% | 0.1 A~72 A | 0.8L~1~0.8C | 0.05%*RD | 0.1%*RD |
6.2.3 Load
Load | Load Power | Single phase 8kW. |
Load Expansion | Supports cascaded three-phase 45kW resistive loads or electric vehicles | |
Heat Dissipation | Forced air cooling | |
Protection | Overvoltage protection, overcurrent protection, abnormal wind speed protection |
6.3 Clock
Clock Function | Timing Method | Satellite timing |
Measurement Uncertainty (k=2) | 1s/d |
6.4 Temperature (Wired Temperature Probe)
Temperature | Measurement Range | -30℃~60℃ |
Maximum Allowable Error | 0.5℃ | |
Note: A Bluetooth temperature and humidity meter can be optionally equipped, please see the optional accessories list for details. |
7. General Specification
Power Supply | There are three power supply modes available: charging gun head, built-in lithium battery, and 220V mains power. | |
power Input | AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz | |
Communication Method | USB, LAN, WIFI, Bluetooth | |
Temperature Performance | Working temperature: -25°C~55°C; Storage temperature: -30°C~70°C | |
Humidity Performance | Working humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C Storage humidity: <80% R H, no condensation | |
Size and Weight | TK4860E-S | TK4860E-T |
• 330(W) * 305(D) * 460(H) • Approx 16kg | • 330(W) * 305(D) * 460(H) • Approx 18kg |
8. Ordering Information
9. Accessory List
S/N | Name | Specification | Qty | Note |
1 | Handheld Bluetooth Thermohygrometer |
| 1 | Optional |
2 | Vehicle Charging Connector |
| 1 | Optional |
3 | Vehicle Charging Connecto |
| 1 | Optional |
Note: The above accessories need to be purchased separately and specified in the order contract. |
6. Specification
6.1 TK4860E-S (Single-Phase)
6.1.1 Single-Phase Voltage/Current
Measurement | Accuracy Class | ||
Class 0.05 | Class 0.1 | ||
Voltage | Range | 220 V | 220 V |
Measurement Range | 220 V ± 20% | 220 V ± 20% | |
Current | Range | 30 A | 30 A |
Measurement Range | 0.1 A~36 A | 0.1 A~36 A | |
Waveform Distortion | Measurement Uncertainty (k=2) | 0.5% | 0.5% |
6.1.2 Single Phase Power/Energy Measurement
Voltage Range | Current Range | Power Factor | Measurement Uncertainty (k=2) | |
Class 0.05 | Class 0.1 | |||
220 V ± 20% | 0.1 A~36 A | 0.8L~1~0.8C | 0.05%*RD | 0.1%*RD |
6.1.3 Load
Load | Load Power | Single phase 8kW, does not support load expansion |
Heat Dissipation | Forced air cooling | |
Protection | Overvoltage protection, overcurrent protection, abnormal wind speed protection |
6.2 TK4860E-T (Three-phase)
6.2.1 Three-Phase Voltage/Current
Measurement | Accuracy Class | ||
Class 0.05 | Class 0.1 | ||
Three-Phase Voltage | Range | 220 V | 220 V |
Measurement Range | 220 V ± 20% (phase voltage) | 220 V ± 20% (phase voltage) | |
Three-Phase Current | Range | 60 A | 60 A |
Measurement Range | 0.1 A~72 A | 0.1 A~72 A | |
Waveform Distortion | Measurement Uncertainty (k=2) | 0.5% | 0.5% |
6.2.2 Three-Phase Power/Energy Measurement
Voltage Range | Current Range | Power Factor | Measurement Uncertainty (k=2) | |
Class 0.05 | Class 0.05 | |||
220 V ± 20% | 0.1 A~72 A | 0.8L~1~0.8C | 0.05%*RD | 0.1%*RD |
6.2.3 Load
Load | Load Power | Single phase 8kW. |
Load Expansion | Supports cascaded three-phase 45kW resistive loads or electric vehicles | |
Heat Dissipation | Forced air cooling | |
Protection | Overvoltage protection, overcurrent protection, abnormal wind speed protection |
6.3 Clock
Clock Function | Timing Method | Satellite timing |
Measurement Uncertainty (k=2) | 1s/d |
6.4 Temperature (Wired Temperature Probe)
Temperature | Measurement Range | -30℃~60℃ |
Maximum Allowable Error | 0.5℃ | |
Note: A Bluetooth temperature and humidity meter can be optionally equipped, please see the optional accessories list for details. |
7. General Specification
Power Supply | There are three power supply modes available: charging gun head, built-in lithium battery, and 220V mains power. | |
power Input | AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz | |
Communication Method | USB, LAN, WIFI, Bluetooth | |
Temperature Performance | Working temperature: -25°C~55°C; Storage temperature: -30°C~70°C | |
Humidity Performance | Working humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C Storage humidity: <80% R H, no condensation | |
Size and Weight | TK4860E-S | TK4860E-T |
• 330(W) * 305(D) * 460(H) • Approx 16kg | • 330(W) * 305(D) * 460(H) • Approx 18kg |
8. Ordering Information
9. Accessory List
S/N | Name | Specification | Qty | Note |
1 | Handheld Bluetooth Thermohygrometer |
| 1 | Optional |
2 | Vehicle Charging Connector |
| 1 | Optional |
3 | Vehicle Charging Connecto |
| 1 | Optional |
Note: The above accessories need to be purchased separately and specified in the order contract. |