Welcome To TUNKIA !      Electrical Measurement    Magnetic Measurement
You are here: Home » Products » Advanced Electrical Reference Standards » TH0780 Multiplexing V/V Selection Units » TH0780 Multiplexing V/V Selection Units

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

TH0780 Multiplexing V/V Selection Units

TH0780  is a high-precision power frequency voltage converter with a built-in multi-range precision voltage transformer. It can convert high power frequency voltage to 1V output voltage signals, enabling precise measurement of power frequency voltages or source voltage traceability calibration.
Availability:
Quantity:
  • TH0780

  • TUNKIA

TH0780 Multiplexing V/V Selection Units

TH0780 Multiplexing V/V Selection UnitsTH0780 Multiplexing VV Selection Units 1

1. Summary

TH0780 is a high-precision power frequency voltage converter with built-in multi-position precision voltage transformers, which can convert large power frequency voltages into 1V output, and realize precise measurement of power frequency voltage or traceable calibration of voltage sources.


2. Feature

U1 Nominal Input: 60 V ~ 480 V

U2 Nominal Output: 1V

Working Frequency: 45 Hz ~ 65 Hz

Ratio Typical Uncertainty: 5 ppm

Select different ratios by touch on the LCD screen.

The voltage output can be turned off or on with one key.


3. Application

Power Frequency Voltage Precision Measurement

Power Frequency Voltage Standard Source Traceability


Power Frequency Voltage Precision Measurement

TH0780 Multiplexing VV Selection Units Measure power frequency voltage

Combined with a precision voltmeter (such as TH0190) to build a precision current measurement system.

Measure power frequency voltage or calibrate power frequency voltage source.


Power Frequency Voltage Standard Source Traceability

TH0780 Multiplexing VV Selection Units Precise Calibration of Power Frequency Voltage Standard Source

The secondary voltage output by TH0780 is compared with the AC voltage reference through the zero voltage meter.

The ultra-high calibration uncertainty realizes the precise traceability of the power frequency voltage standard source.



4. Specification

Primary Nominal Input 

Voltage

Secondary Nominal Output Voltage

Ratio Typical Uncertainty(k=2)

60 V

1 V

5 ppm

120 V

1 V

5 ppm

240 V

1 V

5 ppm

480 V

1 V

5 ppm

 


5. General Specifications


Power Supply

AC ( 220 ± 22 ) V( 50 ± 2 ) Hz

Working Environment

0 °C ~ 40 °C20% R·H ~ 80% R·HNo condensation.

Storage Environment

-10 °C ~ 50 °C10% R·H ~ 90% R·HNo condensation.

Dimensions

483 mm (W) × 400 mm (D) × 177.8 mm (H)without handle

Weight

About 23.5 kg

Communication Interface

RS232×1USB×1LAN×1

 


Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap