TA2000 is a high precision AC Power source standard with wide range, It's applied for calibrating AC power meters、calibrating AC Voltmeter、calibrating AC Ammeter、calibrating Phase Meter and Frequency Meter. The optional electrical energy function can be used for testing single phase AC energy meter and AC Clamp Ammeter.

Availability:
Quantity:
  • TA2000

  • TUNKIA

TA2000 AC Power Calibrator

TA2000 AC Power Calibrator

1. Summary

TA2000 is a high precision AC Power source standard with wide range, It's applied for calibrating AC power meters、calibrating AC Voltmeter、calibrating AC Ammeter、calibrating Phase Meter and Frequency Meter. The optional electrical energy function can be used for testing single phase AC energy meter and AC Clamp Ammeter.


2. Features

ACV output: 0.3 V ~ 1100 V

ACI output: 0.3 mA ~ 110 A

AUX output: 0.5 mV ~ 5.5 V

F: 40 Hz ~ 70 Hz(1500 Hz is optional)

Voltage/Current accuracy: Class 0.02/0.05

Phase accuracy: ±0.01° / ±0.02°

Adjustment fineness: 0.001%

Distortion factor: <0.5%

Harmonic voltage/current output(optional)

AC energy measurement(optional)


3. Application

TA2000 AC Power Calibrator Application


Calibrate AC electrical meter

TA2000 AC Power Calibrator Calibrate AC electrical meter

ACV output: 0.3 V ~ 1100V@40 Hz ~ 70 Hz, 300 V@1.5 kHz

ACI output: 0.3 mA ~ 100 A @40 Hz ~ 70 Hz, 50 A@1.5 kHz

Application for calibrating AC voltage/current meter

1.5 kHz is optional.


Calibrate AC power meter

TA2000 AC Power Calibrator Calibrate AC power meter

Application 1: Output a virtual standard power source through AC current and voltage source, it’s applied for calibrating conventional AC power meter.

Application 2: Output a virtual standard power source through AC small-signal voltage and AC voltage source, it’s applied for calibrating AC power meter with current transducer.

Calibrate active power meter, reactive power meter, volt-ampere meter, power frequency phase meter, power factor meter, power analyzer, etc.


Calibrate AC clamp ammeter(optional)

TA2000 AC Power Calibrator Calibrate AC clamp ammeter(optional)

Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters.


Detect AC energy meter(optional)

TA2000 AC Power Calibrator Detect AC energy meter(optional)

Detect AC energy meter.



4. Characteristics

Wide output range

TA2000 AC Power Calibrator Wide output range


Harmonic output(optional)

TA2000 AC Power Calibrator Harmonic output(optional)

2nd ~ 21th harmonic @ 50 Hz.


Multiple output\adjustment methods

TA2000 AC Power Calibrator Multiple output\adjustment methods

Direct outputmode: the value output can be set directly by physical key or touch screen.

TA2000 AC Power Calibrator Multiple output\adjustment methods 2

Calibration of the analog pointer meter usually needs to test scale by scale, especially "differences between rising and falling" (the change caused by the rise and fall of the calibration point).

Remote box can realize the coarse and fine adjustment of current or voltage.


Multiple output\adjustment methods

TA2000 AC Power Calibrator Multiple output\adjustment methods 3

Direct output” mode: the value output can be set directly by physical key or touch screen.

TA2000 AC Power Calibrator Multiple output\adjustment methods 4

Use the key 10%10%×10÷10 on the front panel, can realize the adjustment of the quantity value, and can also be used to perform the relevant test of linearity.




6. Specifications

6.1 AC Voltage Output

Range

Frequency [1]

Resolution

Voltage Output

Maximum Burden Current

3 V

40 Hz ~ 70 Hz

10 μV

0.30000 V ~ 3.30000 V

500mA

70 Hz ~ 1500 Hz

10 V

40 Hz ~ 70 Hz

100 μV

1.0000 V ~ 11.0000 V

500mA

70 Hz ~ 1500 Hz

30 V

40 Hz ~ 70 Hz

100 μV

3.0000 V ~ 33.0000 V

500mA

70 Hz ~ 1500 Hz

100 V

40 Hz ~ 70 Hz

1 mV

10.000 V ~ 110.000 V

350 mA

70 Hz ~ 1500 Hz

300 V

40 Hz ~ 70 Hz

1 mV

30.000 V ~ 330.000 V

120 mA

70 Hz ~ 1500 Hz

600 V

40 Hz ~ 70 Hz

1 mV

60.000 V ~ 660.000 V

50 mA

1000 V

40 Hz ~ 70 Hz

10 mV

100.00 V ~ 1100.00 V

40 mA

Note: [1] 70 Hz ~ 1500 Hz is optional。

Adjustment fineness: 0.001%*RG, 6 digits display.

Short-circuit and overload protection


Range

Frequency

Short-term Stability

 (±%*RG/min)

Accuracy

±(ppm*RD+ppm*RG) [1]

Distortion Factor (%)

Class 0.05

Class 0.02

Class 0.05

Class 0.02

3 V

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

10 V

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

30 V

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

100 V

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

300 V

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

600 V

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

1000 V

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

Note: [1] RD is reading, RG is range, same below.


6.2 AC Current Output

Range

Frequency [1]

Resolution

Current Output

Maximum Burden Voltage

3 mA

40 Hz ~ 70 Hz

10 nA

0.30000 mA ~ 3.30000 mA

50 V

70 Hz ~ 1500 Hz

10 mA

40 Hz ~ 70 Hz

100 nA

1.0000 mA ~ 11.0000 mA

50 V

70 Hz ~ 1500 Hz

30 mA

40 Hz ~ 70 Hz

100 nA


3.0000 mA ~ 33.0000 mA

50 V

70 Hz ~ 1500 Hz

100 mA

40 Hz ~ 70 Hz

1 μA

10.000 mA ~ 100.000 mA

50 V

70 Hz ~ 1500 Hz

300 mA

40 Hz ~ 70 Hz

1 μA

30.000 mA ~ 330.000 mA

50 V

70 Hz ~ 1500 Hz

1 A

40 Hz ~ 70 Hz

10μA


0.10000 A ~ 1.10000 A

50 V

70 Hz ~ 1500 Hz

3 A

40 Hz ~ 70 Hz

10μA


0.30000 A ~ 3.30000 A

30 V

70 Hz ~ 1500 Hz

10 A

40 Hz ~ 70 Hz

100μA


1.0000 A ~ 10.0000 A

6 V

70 Hz ~ 1500 Hz

30 A

40 Hz ~ 70 Hz

100μA

3.0000 A ~ 33.0000 A

2.5 V

70 Hz ~ 1500 Hz

100 A

40 Hz ~ 70 Hz

1 mA

10.000 A ~ 110.000 A

1.2 V

70 Hz ~ 1500 Hz

10.000 A ~ 50.000 A

Note: [1] 70 Hz ~ 1500 Hz is optional.

Current output: 0.3 mA ~ 110 A @ 40 Hz ~ 70 Hz; 0.3 mA ~ 50 A @ 70Hz ~ 1.5 kHz.

Adjustment Fineness: 0.001%*RG, 6 digits display.

Open-circuit and overload protection


Range

Frequency

Short-term Stability

 (±%*RG/min)

Accuracy

±(ppm*RD+ppm*RG) [1]

Distortion Factor (%)

Class 0.05

Class 0.02

Class 0.05

Class 0.02

3 mA

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

10 mA

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

30 mA

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

100 mA

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

300 mA

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

1 A


40 Hz ~ 70 Hz

0.01


0.005


300 + 200


120 + 80


<0.5

70 Hz ~ 1500 Hz

<1.0

3 A

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

10 A

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

30 A

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0

100 A

40 Hz ~ 70 Hz

0.01

0.005

300 + 200

120 + 80

<0.5

70 Hz ~ 1500 Hz

<1.0


6.3 AC Small-signal Voltage Output

Range

Frequency [1]

Resolution

Voltage Output

Maximum Burden Current

5 mV

40 Hz ~ 70 Hz

10 nV

0.50000 mV ~ 5.50000 mV

10 mA

70 Hz ~ 1500 Hz

20 mV

40 Hz ~ 70 Hz

100 nV

2.0000 mV ~ 22.0000 mV

10 mA

70 Hz ~ 1500 Hz

50 mV

40 Hz ~ 70 Hz

100 nV

5.0000 mV ~ 55.0000 mV

10 mA

70 Hz ~ 1500 Hz

200 mV

40 Hz ~ 70 Hz

1 μV

20.000 mV ~ 220.000 mV

10 mA

70 Hz ~ 1500 Hz

500 mV

40 Hz ~ 70 Hz

1 μV

50.000 mV ~ 550.000 mV

10 mA

70 Hz ~ 1500 Hz

2 V

40 Hz ~ 70 Hz

10μV

0.20000 V ~ 2.20000 V

10 mA

70 Hz ~ 1500 Hz

5 V

40 Hz ~ 70 Hz

10μV

0.50000 V ~ 5.50000 V

10 mA

70 Hz ~ 1500 Hz

Note: [1] 70 Hz ~ 1500 Hz is optional.

Adjustment Fineness: 0.001%*RG, 6 digits display.

Short-circuit and overload protection


Range

Frequency

Short-term Stability

 (±%*RG/min)

Accuracy

±(ppm*RD+μV)

Distortion Factor (%)

Class 0.05

Class 0.02

Class 0.05

Class 0.02

5 mV

40 Hz ~ 70 Hz

0.5

0.2

300 + 20

120 + 10

<1.0

70 Hz ~ 1500 Hz

<1.0

20 mV

40 Hz ~ 70 Hz

0.1

0.05

300 + 20

120 + 10

<1.0

70 Hz ~ 1500 Hz

<1.0

50 mV

40 Hz ~ 70 Hz

0.05

0.02

300 + 20

120 + 10

<1.0

70 Hz ~ 1500 Hz

<1.0

200 mV

40 Hz ~ 70 Hz

0.05

0.02

300 + 100

120 + 60

<0.5

70 Hz ~ 1500 Hz

<1.0

500 mV

40 Hz ~ 70 Hz

0.05

0.02

300 + 100

120 + 60

<0.5

70 Hz ~ 1500 Hz

<1.0

2 V

40 Hz ~ 70 Hz

0.02

0.01

300 + 400

120 + 150

<0.5

70 Hz ~ 1500 Hz

<1.0

5 V

40 Hz ~ 70 Hz

0.02

0.01

300 + 1000

120 + 400

<0.5

70 Hz ~ 1500 Hz

<1.0

Note: [1] RD is reading, RG is range, same below.


6.4 Sinusoidal Wave Frequency Output

Range

Resolution

Accuracy

Class 0.05

Class 0.02

40.0001Hz ~ 99.9999 Hz

0.0001 Hz

±0.02%

±0.01%

100.000 Hz ~ 999.999 Hz

0.001 Hz

±0.02%

±0.01%

1000.00 Hz ~1500.00 Hz

0.01 Hz

±0.02%

±0.01%


6.5 AC Power Output

Frequency Range

(f)

Voltage Range

(U)

Current Range

(I)

Low Voltage Range

(Aux)

Phase Range

(φ)

Power Factor

Range

(λ)

40 Hz ~ 70 Hz

0.3 V ~ 600 V

0.3 mA ~ 110 A

0.5 mV ~ 5.5 V

0°~360°

-1~0~1

70 Hz ~ 1500 Hz

0.3 V ~ 330 V

0.3 mA ~ 50 A

0.5 mV ~ 5.5 V

0°~360°

-1~0~1

Note [1]: active power |sinφ|≥0.5reactive power |cosφ|≥0.5

Note [2]: For more accurate technical indicators of power accuracy or power accuracy under other power factors, please refer to the calculation formula:: is the accuracy of voltage, is the accuracy of current Is the accuracy of power factor.


6.6 Phase and Power Factor Adjustment

Phase


Power factor

Accuracy

Phase

Power factor


WATTS

VARS

λ=cosφ

Class 0.05

Class 0.02

Class 0.05

Class 0.02

90°

1.00000

0.02°

0.01°

0.000%

0.000%

10°

80°

0.98481

0.02°

0.01°

0.006%

0.003%

20°

70°

0.93969

0.02°

0.01°

0.013%

0.006%

30°

60°

0.86603

0.02°

0.01°

0.020%

0.010%

40°

50°

0.76604

0.02°

0.01°

0.029%

0.015%

50°

40°

0.64279

0.02°

0.01°

0.042%

0.021%

60°

30°

0.50000

0.02°

0.01°

0.060%

0.030%

70°

30°

0.34202

0.02°

0.01°

0.096%

0.048%

80°

10°

0.17365

0.02°

0.01°

0.198%

0.099%

90°

0.00000

[1] Phase range: 0.000°~359.999°, adjustment fineness: 0.005°

[2] Power factor range: -1 ~ 0 ~ 1, adjustment fineness: 0.000 1

[3] Other accuracy of power factor formula:

accuracy of power factor formula


6.7 Harmonic Output(optional)

2nd ~ 31th

Amplitude: 0 ~ 40%

Phase: 0.0° ~ 359.9°


6.8 Energy Testing(optional)

Energy pulse output: 60 kHz for high frequency range, 6 Hz for low frequency range

Energy pulse input: frequency ≤200 kHz, voltage amplitude: 0…3.3 V…24 V


7. General Specifications

Power supply

AC (220±22) V, (50±2) Hz

Maximum power

consumption

600 VA

Warm up time

Twice the time since last warmed up, to a maximum of 30 minutes.

Temperature performance

Operating temperature: 0°C~40°C

Calibrating temperature: 18°C~28°C

Storage temperature: -20°C~70°C

Humidity performance

Operating humidity: <80% @ 30°C, <70% @ 40°C

Storage humidity: (20%~80%) R·H, No condensation

Communication interface

RS232

Dimensions


450 mm(W) × 470 mm (D) × 205 mm (H), Handles and feets excluded.

TA2000 AC Power Calibrator Dimensions


Weight

About 30.5 kg


8. Ordering Information

TA2000 AC Power Calibrator Ordering Information



Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap