TUNKIA Silicon Steel Iron Loss Tester

Publish Time: 2024-01-04     Origin: Site


1. Summary


TS2600 is an instrument used to quickly measure the AC magnetic properties of electrical steel sheets. It can quickly measure specific total loss (Ps) of electrical steel sheets.


2. Features


Fast loss testing at multiple loss test points.

It can display a variety of magnetic parameters, including specific total loss (Ps), magnetic polarization (Jm), magnetic field strength (Hm).

Easy operation: the user only needs to put the specimen under the small single sheet tester to test.

Testing results can be saved easily, including test date and time.

Large LCD touch color screen.



3. Specifications


Testing   Capability

Test point

P1.0、P1.5、P1.7 [1]

Frequency

50 Hz / 60 Hz

Uncertainty of Voltage and Current (k=2)

0.2%*RG [2]

Uncertainty of Active Power

0.5%*FS [3]

Uncertainty of Ps (k=2)

10%

Repeatability of Ps

2%

Specimens

Size (L × W)

≥ 30 mm × 100 mm

Thickness

0.1 mm~1.0 mm

Other Requirements

The surface should be clean, flat, free from spots and scratches


• Note: [1] P1.7 is the test point of orientation steel;

• Note: [2] RG is range;

• Note: [3] FS= Voltage range x current range, when the phase Angle is within 75 degrees.

Repeatability: put the same specimens in the specified position and keep it from moving, and measure it repeatedly for 10 times. Take the maximum or minimum value of 10 measurements minus the average value divided by the average value, and the maximum value of the two represents repeatability.


4. Operation Video