1. Summary
TH0190 is a handheld precision AC current pressure gauge that can accurately measure the range of 20 mV ~ 10 V small-signal voltages, and the AC voltage measurement capability is better than 8-digit semi-high-precision standard digital multimeter.
2. Features
• Frequency range: DC, 40 Hz ~ 10 kHz.
• DC measurement uncertainty up to 30 ppm.
• Cross-current measurement uncertainty up to 50 ppm@53 Hz.
• 2~64th harmonic measurement, DC ripple measurement function.
• LCD color screen, digital button operation.
3. Applications
• Accurate measurement of AC and DC voltage and current on site
• Calibrate AC and DC voltage standard sources/meters, current standard sources/meters
☆ Measure the AC/DC voltage |
|
• It can be used with precision voltage divider (such as TH0150 / TH0170) formation of AC/DC voltage measurement system. • It can be used to measure the AC/DC voltage, AC/DC voltage source. |
☆ Measure AC-DC current |
|
• It can be used with I/V conversion standards (such as TH0400 / TH0500U) to form an AC/DC current measurement system. • It can be used for measuring AC/DC current signal, the calibration of AC/DC current source. |
4. Characteristics
☆ Measure ripple or distortion |
|
• The instrument supports DC, AC measurement mode, AC frequency range: 40 Hz ~ 10 kHz. • When measuring voltage, distortion and ripple measurements can be completed simultaneously, the maximum measurement bandwidth of DC ripple is up to 1 kHz, and AC supports the measurement of the 2nd ~ 64th harmonic. |
5. Specifications
Voltage range | Measurement uncertainty (k=2, ppm*RD+ppm*RG )[1]. | Temperature coefficient (±ppm*RG/°C) | |
DC | AC @ 53 Hz | ||
200 mV | 18 + 12 | 30 + 20 | <1.0 |
1 V | 18 + 12 | 30 + 20 | <1.0 |
10 V | 18 + 12 | 30 + 20 | <1.0 |
Note [1]: RD is the reading value and RG is the range value |
6. General Specifications
Power supply | 4000 mAh lithium battery powered, USB charging |
Temperature performance | Working temperature: 18°C ~ 28°C Storage temperature: 0°C ~ 40°C |
Humidity performance | Operating humidity:(20%~85%) R·H, no condensation Storage humidity: <95% R·H, no condensation |
Altitude | < 3000 m |
Size | 165 mm (W) ×90 mm (D)×40 mm (H) |
Quality | Approx. 0.5 kg |
Input interface | LEMO plugs |
Communication interface | USB interface |
Advanced Multifunction Calibrator Advanced Electrical Reference Standards Electric Vehicle (EV)Charging Facility Tester AC/DC Standard Source /Meter Single-phase/Three-phase Standard Meter Magnetic Parameters Measurement and Calibration Magnetic Material Testing Equipment Electrical Steel Testing Equipment