1. Summary
TD1000 is a calibration apparatus for multifunctional clamp meters, which integrates functions such as AC/DC high current standard source, AC/DC voltage standard source, and resistance standard source, which can meet the calibration needs of multifunctional clamp meters with different accuracy levels.
2. Features
• Accuracy: Class 0.05, Class 0.1 available
• AC current output: 20 mA ~ 1100 A
• AC voltage output: 1 V ~ 825 V
• DC current output(optional): 20 mA ~ 22A
• DC voltage output(optional): 20 mV ~ 1100V
• DC resistance output: 10 Ω ~ 11 MΩ
• Two thickness copper rings
• Remote adjustment(optional)
3. Application
☆Calibrate AC Clamp Meter by Single-turn Method |
|
• ACI output: 20 mA ~ 1100 A, 45 Hz ~ 65 Hz • Two thickness copper rings. |
☆ Calibrate DC Clamp meters by Equivalent Ampere-turn Method(optional) |
|
• DCI output: 20 mA ~ 22 A • Coil: 50 T, accuracy ± 0.3% • Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters. |
☆ Calibrate Multi-function Clamp Meters |
|
• ACV output: 1 V ~ 825 V, 45 Hz ~ 65 Hz • DCV output: 20 mV ~ 1100V • RES output: 10 Ω ~ 11 MΩ • Calibrate AC/DC Voltmeters and DC Resistance Meters |
4. Panel Features
| |
Item | Description |
| Current Source, Output AC\DC current. |
| Copper Ring 1, I≤100 A(AC). |
| Copper Ring 2, I>100 A(AC). |
| 50T Coil, used to calibrate the DC Clamp meters by amplifing the DC current. |
| Wiring Panel, integrates the output terminals, power switchs and e-stop. |
| Operate Panel, adjust electric parameter of the device. |
| Workbench, Used to settle the device. |
5. Characteristics
☆ Convenient Traceability |
|
• Calibrate the AC current source through accessing the standard ammeter (TH0630 Precision Through Core AC Ammeter) to the current loop. |
☆Wide Output Range |
|
☆ Output and Adjustment |
|
• “Direct output”mode: the value output can be set directly by clicking the touch panel. |
|
• Calibration of the analog pointer meter usually needs to test scale by scale, especially "differences between rising and falling" (the change caused by the rise and fall of the calibration point). |
6. Specifications
6.1 AC Current
Range | Resolution | Output Range | Frequency | Max Compliance Voltage (rms) |
200 mA | 1 μA | 10.000 mA ~ 210.000 mA | 45 Hz ~ 65 Hz | 50 V |
1 A | 10 μA | 0.10000 A ~ 1.10000 A | 45 Hz ~ 65 Hz | 15 V |
5 A | 10 μA | 0.50000 A ~ 5.50000 A | 45 Hz ~ 65 Hz | 8 V |
20 A | 100 μA | 2.0000 A ~ 22.0000 A | 45 Hz ~ 65 Hz | 2 V |
50 A | 100 μA | 5.0000 A ~ 55.0000 A | 45 Hz ~ 65 Hz | 1 V |
100 A | 1 mA | 10.000 A ~ 110.000 A | 45 Hz ~ 65 Hz | 0.7 V |
250 A | 1 mA | 25.000 A ~ 275.000 A | 45 Hz ~ 65 Hz | 0.7 V |
500 A | 1 mA | 50.000 A ~ 550.000 A | 45 Hz ~ 65 Hz | 0.7 V |
1000 A | 10 mA | 100.00 A ~ 1100.00 A | 45 Hz ~ 65 Hz | 0.7 V |
Range | Stability (± %/min) | Accuracy ± (ppm*RD+ppm*RG) | Distortion (%) | ||
Class 0.05 | Class 0.1 | Class 0.05 | Class 0.1 | ||
200 mA | 0.01 | 0.02 | 250 + 150 | 600 + 400 | <0.5 |
1 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
5 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
20 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
50 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
100 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
250 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
500 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
1000 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | < 0.5 |
Note[1]: RD=Reading,RG=Range, unless otherwise noted; |
• Output range: 20 mA ~ 1100 A
• Adjustment fineness: 0.002%*RG,6 digits display
• Protections: open-circuit protection, overload protection, over-heat protection
6.2 AC Voltage
Range | Resolution | Output Range | Frequency | Max Burden(rms) |
10 V | 100 μV | 1.0000 V ~ 11.0000 V | 45 Hz ~ 65 Hz | 800 mA |
30 V | 100 μV | 3.0000 V ~ 33.0000 V | 45 Hz ~ 65 Hz | 700 mA |
100 V | 1 mV | 10.000 V ~ 110.000 V | 45 Hz ~ 65 Hz | 200 mA |
300 V | 1 mV | 30.000 V ~ 330.000 V | 45 Hz ~ 65 Hz | 70 mA |
750 V | 1 mV | 75.000 V ~ 825.000 V | 45 Hz ~ 65 Hz | 30 mA |
Range | Stability (±/min) | Accuracy ± (ppm*RD+ppm*RG) | Distortion (%) | ||
Class 0.05 | Class 0.1 | Class 0.05 | Class 0.1 | ||
10 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | <0.5 |
30 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
100 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
300 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
750 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
• Adjustment fineness: 0.002%*RG
• 6 digits display
• Protections: short-circuit protection, overload protection, over-heat protection
6.3 DC Current(optional)
Range | Resolution | Output Range | Max Compliance Voltage |
200 mA | 1 μA | 20.000 mA ~ 220.000 mA | 10 V |
1 A | 10 μA | 0.10000 A ~ 1.10000 A | 10 V |
5 A | 10 μA | 0.50000 A ~ 5.50000 A | 10 V |
20 A | 100 μA | 2.0000 A ~ 22.0000 A | 10 V |
Range | Stability (± %/min) | Accuracy ± (ppm*RD+ppm*RG) [2] | Ripple Factor (%) | ||
Class 0.05 | Class 0.1 | Class 0.05 | Class 0.1 | ||
200 mA | 0.01 | 0.02 | 250 + 150 | 600 + 400 | <0.5 |
1 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | <0.5 |
5 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | <0.5 |
20 A | 0.01 | 0.02 | 250 + 150 | 600 + 400 | <0.5 |
• Output range: 20 mA ~ 22 A(1000 At)
• Adjustment fineness: 0.002%*RG
• Display digits: 6 digits display
• Protections: open-circuit protection, overload protection, over-heat protection
6.4 DC Voltage(optional)
Range | Resolution | Output Range | Max Burden |
200 mV | 1 μV | 20.000 mV ~ 220.000 mV | 100 mA |
1 V | 10 μV | 0.10000 V ~ 1.00000 V | 100 mA |
10 V | 100 μV | 1.0000 V ~ 11.0000 V | 100 mA |
30 V | 100 μV | 3.0000 V ~ 33.0000 V | 800 mA |
100 V | 1 mV | 10.000 V ~ 110.000 V | 200 mA |
300 V | 1 mV | 30.000 V ~ 330.000 V | 70 mA |
600 V | 1 mV | 60.000 V ~ 660.000 V | 25 mA |
1000 V | 10 mV | 100.00 V ~ 1100.00 V | 20 mA |
Range | Stability (± %/min) | Accuracy ± (ppm*RD+ppm*RG) | Ripple Factor (%) | ||
Class 0.05 | Class 0.1 | Class 0.05 | Class 0.1 | ||
200 mV | 0.01 | 0.02 | 300 + 200 | 600 + 400 | <0.5 |
1 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
10 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
30 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
100 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
300 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
600 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
1000 V | 0.01 | 0.02 | 300 + 200 | 600 + 400 | < 0.5 |
• Output range: 20 mV ~ 1100 V
• Adjustment fineness: 0.002%*RG
• 6 digits display
• Protections: short-circuit protection, overload protection, over-heat protection
6.5 DC Resistance
Range | Resolution | Output Range | Accuracy ± (ppm*RD+ppm*RG) | Allowable Current |
100 Ω | 1 mΩ | 10.000 Ω ~ 110.000 Ω | 600 + 400 | 1 mA ~ 15 mA |
1 kΩ | 10 mΩ | 0.10000 kΩ ~ 1.10000 kΩ | 600 + 400 | 100 μA ~ 1.5 mA |
10 kΩ | 100 mΩ | 1.0000 kΩ ~ 11.0000 kΩ | 600 + 400 | 10 μA ~ 150 μA |
100 kΩ | 1 Ω | 10.000 kΩ ~ 110.000 kΩ | 600 + 400 | 10 μA ~ 150 μA |
1 MΩ | 10 Ω | 0.10000 MΩ ~ 1.10000 MΩ | 600 + 400 | 1 μA ~ 15 μA |
10 MΩ | 100 Ω | 1.0000 MΩ ~ 11.0000 MΩ | 600 + 400 | 100 nA ~ 2 nA |
• Output range: 10 Ω ~ 11 MΩ
• Adjustment fineness: 0.002%*RG
• 6 digits display
7. Ordering Information
8. General Specifications
Power supply | AC (220 ± 22) V,(50 ± 2) Hz |
Max power consumption | 2.5 kVA |
Operating condition | 0°C ~ 40°C,(20% ~ 85%) R·H,non-condensing |
Storage condition | -20°C ~ 70°C,(10% ~ 95%) R·H,non-condensing |
Standard interfaces | RS 232 |
Dimensions | 2310 mm (W)×750 mm (D)×1280 mm (H) |
|
Advanced Multifunction Calibrator Advanced Electrical Reference Standards Electric Vehicle (EV)Charging Facility Tester AC/DC Standard Source /Meter Single-phase/Three-phase Standard Meter Magnetic Parameters Measurement and Calibration Magnetic Material Testing Equipment Electrical Steel Testing Equipment