TM2000 / 2030
TUNKIA
*The drawing is for reference only. There may be some differences according to different technical specifications
1. Summary
The TM2000 / 2030 is a series of precision excitation current sources with high precision, high resolution regulation, high stability and other characteristics. It can be used as excitation power supply of field generator such as Helmholtz coil and solenoid to generate standard magnetic field. It’s applied for the influence test of materials, devices and instruments or the calibration of magnetic sensors and other applications.
2. Features
• Single or three channel output are optional.
• Current output can produce a magnetic field.
• Optimal short-term stability is 20ppm/min.
• Open loop or closed loop two test modes.
• Open loop can set current or magnetic field value output.
• Closed loop can realize feedback measurement with magnetic sensor.
• Support a variety of value setting and adjustment.
• Support cascaded expansion of current or power output.
• Open circuit, overload, and overheating protection.
*The drawing is for reference only. There may be some differences according to different technical specifications
1. Summary
The TM2000 / 2030 is a series of precision excitation current sources with high precision, high resolution regulation, high stability and other characteristics. It can be used as excitation power supply of field generator such as Helmholtz coil and solenoid to generate standard magnetic field. It’s applied for the influence test of materials, devices and instruments or the calibration of magnetic sensors and other applications.
2. Features
• Single or three channel output are optional.
• Current output can produce a magnetic field.
• Optimal short-term stability is 20ppm/min.
• Open loop or closed loop two test modes.
• Open loop can set current or magnetic field value output.
• Closed loop can realize feedback measurement with magnetic sensor.
• Support a variety of value setting and adjustment.
• Support cascaded expansion of current or power output.
• Open circuit, overload, and overheating protection.
3. Specifications
3.1 Constant Current Output
Specifications | TM20X0-5A-30V | TM20X0-25A-12V | TM20X0-25A-24V | |
Current range | 1A, 5A | 1A, 5A, 25A | 1A, 5A, 25A | |
Short-term stability ( ppm/min ) | Class 0.05 | 100 | 100 | 100 |
Class 0.02 | 50 | 50 | 50 | |
Class 0.01 | 30 | 30 | 30 | |
Class 0.005 | 20 | 20 | 20 | |
Accuracy ± (ppm of reading + ppm of range) ① | Class 0.05 | 300 + 200 | 300 + 200 | 300 + 200 |
Class 0.02 | 120 + 80 | 120 + 80 | 120 + 80 | |
Class 0.01 | 60 + 40 | 60 + 40 | 60 + 40 | |
Class 0.005 | 30 + 20 | 30 + 20 | 30 + 20 | |
Maximum load voltage of single channel② | 30 V | 12 V | 24 V | |
Maximum load Power of single channel | 150W | 300W | 600W | |
Note: ①(ppm = parts per million) (e.g., 10ppm = 0.001%) ②The above is the compliance voltage of the base model , and the maximum compliance voltage after cascade is proportional to the maximum power. |
3.2 Magnetic Field Measurement(Optional)
Fluxgate | Range | 100μT, 1mT, 2mT |
Measuring range | 1μT~2mT | |
Display digits | 5-dights display | |
Probe | Single or triaxial fluxgate probes | |
Accuracy | ±0.5% | |
Teslameter | Range | 30mT, 300 mT, 3000 mT |
Measuring range | 2 mT~3600 mT | |
Display digits | 5-dights display | |
Accuracy | 0.5% |
4. Ordering Information
3. Specifications
3.1 Constant Current Output
Specifications | TM20X0-5A-30V | TM20X0-25A-12V | TM20X0-25A-24V | |
Current range | 1A, 5A | 1A, 5A, 25A | 1A, 5A, 25A | |
Short-term stability ( ppm/min ) | Class 0.05 | 100 | 100 | 100 |
Class 0.02 | 50 | 50 | 50 | |
Class 0.01 | 30 | 30 | 30 | |
Class 0.005 | 20 | 20 | 20 | |
Accuracy ± (ppm of reading + ppm of range) ① | Class 0.05 | 300 + 200 | 300 + 200 | 300 + 200 |
Class 0.02 | 120 + 80 | 120 + 80 | 120 + 80 | |
Class 0.01 | 60 + 40 | 60 + 40 | 60 + 40 | |
Class 0.005 | 30 + 20 | 30 + 20 | 30 + 20 | |
Maximum load voltage of single channel② | 30 V | 12 V | 24 V | |
Maximum load Power of single channel | 150W | 300W | 600W | |
Note: ①(ppm = parts per million) (e.g., 10ppm = 0.001%) ②The above is the compliance voltage of the base model , and the maximum compliance voltage after cascade is proportional to the maximum power. |
3.2 Magnetic Field Measurement(Optional)
Fluxgate | Range | 100μT, 1mT, 2mT |
Measuring range | 1μT~2mT | |
Display digits | 5-dights display | |
Probe | Single or triaxial fluxgate probes | |
Accuracy | ±0.5% | |
Teslameter | Range | 30mT, 300 mT, 3000 mT |
Measuring range | 2 mT~3600 mT | |
Display digits | 5-dights display | |
Accuracy | 0.5% |