TH3600 Broadband Low Current Standard Power Source

TH3600 is a three-phase standard power source with wide frequency and low current output. The output bandwidth is 45 Hz~1kHz, and the low current output can be as low as 20μA. It can be used as a power/energy calibration source for high-precision current measurement and analysis below 120mA. It makes up for the serious shortcomings of traditional electric energy meter calibration devices in broadband and low current measurement. It has optional power accuracy of class 0.005 and 0.01.
Availability:
Quantity:
  • TH3600

  • TUNKIA


TH3600 Broadband Low Current Standard Power Source



1.Summary

TH3600 is a three-phase standard power source with wide frequency and low current output. The output bandwidth is 45 Hz~1kHz, and the low current output can be as low as 20μA. It can be used as a power/energy calibration source for high-precision current measurement and analysis below 120mA. It makes up for the serious shortcomings of traditional electric energy meter calibration devices in broadband and low current measurement. It has optional power accuracy of class 0.005 and 0.01.


2.Features

• Maximum output: 528 V / 120 mA, which can ensure the stability of value output under full load conditions.

• Minimum current output: as low as 20μA.

• Multi-functional electric energy measurement: It has forward, reverse active and reactive energy, and supports the calibration of electric energy meters.

• Harmonic function (optional): Can load 2nd to 63rd harmonics with adjustable amplitude and phase to complete the harmonic impact test.

3. Specification

3.1 ACV Output

Range

Resolution

Load Capacity

Short-term Stability

( ppm / min )

Measurement Uncertainty

( ppm*RD+ppm*RG,45Hz~65Hz)

Total Harmonic Distortion

(THD, % )

Class 0.005

Class 0.01

Class 0.005

Class 0.01

60 V

0.01 mV

0.3A

5

10

12 + 8

25 + 15

< 0.01

120 V

0.1 mV

0.15A

5

10

12 + 8

25 + 15

< 0.01

240 V

0.1 mV

0.08A

5

10

12 + 8

25 + 15

< 0.01

480 V

0.1 mV

0.04A

5

10

12 + 8

25 + 15

< 0.01

• Output range: 6 V ~ 528 V, 7-digit display

• Adjustment fineness: 3ppm

• Protection functions: short circuit protection, overload protection, temperature protection


3.2 ACI Output

Range

Resolution

Load Capacity

Short-term Stability

( ppm / min )

Measurement Uncertainty

( ppm*RD+ppm*RG,45Hz~65Hz)

Total Harmonic Distortion

(THD, % )

Class 0.005

Class 0.01

Class 0.005

Class 0.01

0.2 mA

0.1 nA

8V

12

20

30 + 20

50 + 30

< 0.02

0.5 mA

0.1 nA

8V

12

20

30 + 20

50 + 30

< 0.02

1 mA

1 nA

8V

8

15

20 + 10

30 + 20

< 0.02

2 mA

1 nA

8V

8

15

20 + 10

30 + 20

< 0.01

5 mA

1 nA

8V

8

15

20 + 10

30 + 20

< 0.01

10 mA

10 nA

8V

8

15

20 + 10

30 + 20

< 0.01

20 mA

10 nA

8V

8

15

20 + 10

30 + 20

< 0.01

50 mA

10 nA

8V

8

15

20 + 10

30 + 20

< 0.01

100 mA

100 nA

8V

8

15

20 + 10

30 + 20

< 0.01

• Output range: 0.02 mA~120 mA, 7-digit display

• Adjustment fineness: 3ppm

• Protection functions: open circuit protection, overload protection, temperature protection


3.3 Frequency / Phase

Parameter

Adjustment Range

Optimal Measurement Uncertainty (k=2)

Frequency

45.0000 Hz~1000.000 Hz

50 ppm*RD

Phase

0.000 0°~359.9999°

0.001°

Harmonic (optional)

2nd~63rd, amplitude 0~40% (total harmonic distortion does not exceed 50%), phase adjustable from 0.0°~ 359.99°


3.4 Power / Energy

Measured Power

Voltage Range

Current Range

Measurement Uncertainty

(45Hz~65Hz,k=2)

Class 0.005

Class 0.01

Active Power / Energy

Apparent Power

|cos| ≥ 0.5

30 V ≤ U ≤ 480 V

0.05 mA ≤ I ˂1 m A

0.005%*FS

0.01%*FS

1 mA ≤ I < 100 mA

0.005%*RD

0.01%*RD

Reactive Power

|sin| ≥ 0.5

30 V ≤ U ≤ 480 V

0.05 mA ≤ I ˂1 m A

0.01%*FS

0.02%*FS

1 mA ≤ I < 100 mA

0.01%*RD

0.02%*RD

Power Factor

30 V ≤ U ≤ 480 V

0.05 mA ≤ I ˂1 m A

0.01%

0.02%

1 mA ≤ I < 100 mA

0.005%

0.01%

Note: ① FS = voltage range value x current range value

• Power/electric energy measurement range: combination of AC voltage range and AC current range

• Power factor measurement range: -1.000 00…0.000 00…1.000 00

• Standard electric energy pulse output: high frequency full scale value corresponds to 60 kHz, low frequency full scale value corresponds to 6 Hz

• Standard power pulse input: frequency ≤ 200 kHz, voltage: 0…3.3 V…24 V

• Power error display: automatic, resolution 0.0001%


4. General Specification

Power Supply

AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz

Preheat Time

30mins

Temperature Performance

Working temperature: 15°C~30°C;

Storage temperature: -10°C~55°C

Humidity Performance

Working humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C

Storage humidity: (20%~80%) R H, non-condensing

Communication Interface

RS232, LAN


5. Ordering Information

TH3600 Broadband Low Current Standard Power Source TUNKIA



Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap