Welcome To TUNKIA !      Electrical Measurement    Magnetic Measurement
You are here: Home » Products » Single-phase/Three-phase Energy Meter standard Calibration Device » TD3740 Energy Meter Durability Test Device » TD3740 Energy Meter Durability Test Device

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

TD3740 Energy Meter Durability Test Device

TD3740 is a device specially designed to meet the durability test of R46 single-phase/three-phase AC energy meters. The device consists of a standard power source, a meter rack, etc., including three types: TD3740-S (single-phase), TD3740-T (three-phase) and TD3740-ST (single-phase and three-phase compatible). The power/electric energy accuracy is class 0.05. It can be used with high and low temperature test chambers to complete energy meter durability tests and other testing projects.
Availability:
Quantity:
  • TD3740

  • TUNKIA

TD3740 Energy Meter Durability Test Device

TUNKIA TD3740 Energy Meter Durability Test Device

*Reference only. Configurations and details may vary depending on the application scenario.

1. Summary

TD3740 is a device specially designed to meet the durability test of R46 single-phase/three-phase AC energy meters. The device consists of a standard power source, a meter rack, etc., including three types: TD3740-S (single-phase), TD3740-T (three-phase) and TD3740-ST (single-phase and three-phase compatible). The power/electric energy accuracy is class 0.05. It can be used with high and low temperature test chambers to complete energy meter durability tests and other testing projects.


2. Features

Three-phase output: maximum voltage 456 V, maximum current 120 A.

High reliability: Continuous operation at the load point (1.1Umax, Imax) for 1000h can ensure the stability of the value output.

Phase diagram display: The phase between the three-phase electricity can be adjusted arbitrarily, and it can display phase diagram.

The software has comprehensive data management functions, convenient data retrieval, and automatic backup function.

The software can output statistical reports such as verification certificates and test reports; it supports document saving and printing in multiple formats.


3. Appearance

Instruments Introduction

TUNKIA TD3740 Energy Meter Durability Test Device

S/N

Description

Multi-meter error display screen

Standard meter (optional)

Standard power source

Power switch and emergency stop switch

Meter hanging rack


4. Specification

4.1 Voltage Output

Range

Resolution

Short-term Stability

( % / min )

Measurement Uncertainty (k=2)

( ppm*RD+ppm*RG) [1]

Distortion

( % )

60 V

0.1 mV

0.01

200 + 50

< 0.3

120 V

1 mV

0.01

200 + 50

< 0.3

240 V

1 mV

0.01

200 + 50

< 0.3

380 V(Three-phase only)

1 mV

0.01

200 + 50

< 0.3

Note [1]: RD is the reading, RG is the range, the same below

• Output range: single-phase 6~264 V, three-phase 6 V~456 V,

• 6-digit display, load capacity: 15 VA/(phase/meter position)

• Symmetry: voltage ≤ 0.2%, phase ≤ 0.5°

• Protection function: short circuit protection, overload protection


4.2 Current Output

Range

Resolution

Short-term Stability

( % / min )

Measurement Uncertainty (k=2)

( ppm*RD+ppm*RG)

Distortion

( % )

50 mA

0.1μA

0.02

200 + 50

< 0.5

100 mA

1μA

0.01

200 + 50

< 0.5

200 mA

1μA

0.01

200 + 50

< 0.5

500 mA

1μA

0.01

200 + 50

< 0.5

1 A

10μA

0.01

200 + 50

< 0.5

2 A

10μA

0.01

200 + 50

< 0.5

5 A

10μA

0.01

200 + 50

< 0.5

10 A

100μA

0.01

200 + 50

< 0.5

20 A

100μA

0.01

200 + 50

< 0.5

50 A

100μA

0.01

200 + 50

< 0.5

100 A

1mA

0.01

200 + 50

< 0.5

Output range: 5 mA ~ 120 A, 6-digit display, load capacity: 30 VA / (phase/meter position)

Symmetry: current ≤ 0.5%, phase ≤ 0.5°

Protection function: open circuit protection, overload protection


4.3 Frequency/Phase

Frequency

Measuring range

45 Hz ~ 65 Hz

Minimum resolution

0.000 01 Hz

Measurement uncertainty (k=2)

0.005%*RD

Phase

(I ≥ 50mA)

Measuring range

0 ~ 360°

Minimum resolution

0.000 1°

Measurement uncertainty (k=2)

0.012°


4.4 Power/Energy

Current Range

Power Factor

Measurement Uncertainty (k=2)

50 mA ≤ I ≤120 A

0.5L~1~0.5C

0.05%*RD

10 mA ≤ I < 50 mA

1

0.05%*RD

0.5L~1~0.5C

0.08%*RD

5 mA ≤ I < 10 mA

1

0.08%*RD

0.5L~1~0.5C

0.15%*RD

• Output power stability: 0.02% / 2min;

• Power/ energy measurement range: combination of AC voltage range and AC current range;

• Power factor measurement range: -1.000 00…0.000 00…1.000 00;

• Standard energy pulse output: high frequency full range value corresponds to 60 kHz, low frequency full range value corresponds to 6 Hz;

• Standard electric energy pulse input: frequency ≤ 200 kHz, voltage: 0…3.3 V…24 V;

• Energy error display: automatic, with a resolution of 0.0001%.


5. General Specification

Power Supply

Single-phase AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz

Warm-up Time

30-min

Temperature Performance

Working temperature: 5°C~45°C;

Storage temperature: 10°C~55°C

Humidity Performance

Working humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C

Storage humidity: (20%~80%) R H, no condensation

Altitude

< 3000 m

Communication Interface

RS232


6. Ordering Information

TUNKIA TD3740 Energy Meter Durability Test Device


Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap