TD1050 Calibration Device for Clamp Meter

TD1050 is a calibration apparatus for multifunctional clamp meters, which integrates functions such as AC/DC high current standard source, AC/DC voltage standard source, and resistance standard source, and also has AC/DC power output function, which can meet the calibration needs of multifunctional clamp meters with different accuracy levels.
Availability:
Quantity:
  • TD1050

  • TUNKIA

TD1050 Clamp Meters Calibration Device

TUNKIA TD1050 Calibration Device for Clamp Meter

1. Summary

TD1050 is a calibration apparatus for multifunctional clamp meters, which integrates functions such as AC/DC high current standard source, AC/DC voltage standard source, and resistance standard source, and also has AC/DC power output function, which can meet the calibration needs of multifunctional clamp meters with different accuracy levels.


2. Features

• Accuracy: Class 0.05

• DC current: 10 mA ~ 1050 A(2100 A is optional)

• AC current output: 10 mA ~ 1020 A(2050 A is optional)

• DC voltage output(optional): 20 mV ~ 1100 V

• AC voltage output(optional): 1 V ~ 825 V

• Frequency: 40 Hz ~ 400 Hz

• DC resistance output(optional): 10 Ω ~ 11 MΩ

• Two thickness copper rings

• AC/DC power output(optional)


3. Application

TUNKIA TD1050 Calibration Device for Clamp Meter


☆ Calibrate Clamp Meter by Single-turn Method

TUNKIA TD1050 Calibration Device for Clamp Meter

• DCI output: 10 mA~1050 A(2100 A is optional)

• ACI output: 10 mA~1020 A(2050 A is optional), 40 Hz ~ 400 Hz

• Calibrate AC\DC clamp ammeters


☆ Calibrate Clamp Power Meters(optional)

TUNKIA TD1050 Calibration Device for Clamp Meter

• Integrates AC\DC current and voltage standard source, the U-I phase can be adjusted, which is suitable for calibrating clamp power meters.


☆Calibrate Multi-function Clamp Meters(optional)

TUNKIA TD1050 Calibration Device for Clamp Meter

• DCV output: 20 mV ~ 1100V

• ACV output: 1 V ~ 825 V, 40 Hz ~ 400 Hz

• RES output range: 10 Ω ~ 11 MΩ

• Calibrate AC/DC voltmeter and DC resistance meter



4. Panel Features

TUNKIA TD1050 Calibration Device for Clamp Meter


S/N

Description

Current Source, Output AC\DC current.

Copper Ring 1, I≤110 A.

Copper Ring 2, I>100 A.

Workbench, used to settle the device.

Operate Panel, adjust electric parameter of the device.

Voltage Output terminals

Resistance Output terminals

Operate Panel terminal, connected to the control panel.

RS232 Interface,.

Power Switch

E-Stop, Used to stop the power supply in an emergency


5. Characteristics

☆ Convenient Traceability

TUNKIA TD1050 Calibration Device for Clamp Meter

• Calibrate the AC\DC current source through accessing the standard ammeter(TH0630 or TH0530)to the current loop.


☆ Wide Output Range

TUNKIA TD1050 Calibration Device for Clamp Meter


☆ Output and Adjustment

TUNKIA TD1050 Calibration Device for Clamp Meter

• “Direct output”mode: the value output can be set directly by clicking the touch panel.

TUNKIA TD1050 Calibration Device for Clamp Meter

• Calibration of the analog pointer meter usually needs to test scale by scale, especially "differences between rising and falling" (the change caused by the rise and fall of the calibration point).



6. Specifications

6.1 DC Current

Copper Ring

Range

Resolution

Output Range

Max Load

Ring 1

100 mA

1 μA

10.000 mA ~ 110.000 mA

8 V

300 mA

1 μA

30.000 mA ~ 330.000 mA

8 V

1 A

10 μA

0.10000 A ~ 1.10000 A

8 V

3 A

10 μA

0.30000 A ~ 3.30000 A

8 V

10 A

100 μA

1.0000 A ~ 11.0000 A

8 V

30 A

100 μA

3.0000 A ~ 33.0000 A

8 V

100 A

1 mA

10.000 A ~ 110.000 A

8 V

Ring 2

250 A

1 mA

20.000 A ~ 275.000 A

8 V

500 A

1 mA

50.000 A ~ 550.000 A

8 V

1000 A

10 mA

100.00 A ~ 1050.00 A

8 V

2000 A [1]

10 mA

200.00 A ~ 2100.00 A

8 V

Note[1]: 2000 A is Optional

Range

Stability (± %/min)

Accuracy

± (ppm*RD+ppm*RG) [2]

Ripple Factor (%)

100 mA

0.01

300 + 100

<0.5

300 mA

0.01

300 + 100

< 0.5

1 A

0.01

300 + 100

< 0.5

3 A

0.01

300 + 100

< 0.5

10 A

0.01

300 + 100

< 0.5

30 A

0.01

300 + 100

< 0.5

100 A

0.01

300 + 100

< 0.5

250 A

0.01

300 + 100

< 0.5

500 A

0.01

300 + 100

< 0.5

1000 A

0.01

300 + 100

< 0.5

2000 A

0.01

300 + 100

< 0.5

Note[2]: RD=Reading,RG=Range, unless otherwise noted;

• Output range: 10 mA ~ 1050 A\2100 A

• Manual or automatic range switch.

• Adjustment fineness: 0.002%*RG

• 6 digits decimal display

• Protections: open-circuit protection, overload protection, over-heat protection


6.2 AC Current

Copper Ring

Range

Resolution

Output Range

Frequency

Max Compliance Voltage(rms)

Ring 1

100 mA

1 μA

10.000 mA ~ 110.000 mA

40 Hz ~ 400 Hz

6 V

300 mA

1 μA

30.000 mA ~ 330.000 mA

40 Hz ~ 400 Hz

6 V

1 A

10 μA

0.10000 A ~ 1.10000 A

40 Hz ~ 400 Hz

6 V

3 A

10 μA

0.30000 A ~ 3.30000 A

40 Hz ~ 400 Hz

6 V

10 A

100 μA

1.0000 A ~ 11.0000 A

40 Hz ~ 400 Hz

6 V

30 A

100 μA

3.0000 A ~ 33.0000 A

40 Hz ~ 400 Hz

6 V

100 A

1 mA

10.000 A ~ 110.000 A

40 Hz ~ 400 Hz

6 V

Ring 2

250 A

1 mA

20.000 A ~ 275.000 A

40 Hz ~ 400 Hz

6 V

500 A

1 mA

50.000 A ~ 550.000 A

40 Hz ~ 400 Hz

6 V

1000 A

10 mA

100.00 A ~ 1020.00 A

40 Hz ~ 400 Hz

6 V

2000 A [3]

10 mA

200.00 A ~ 2050.00 A

40 Hz ~ 400 Hz

6 V


Range

Stability

(± %/min)

Accuracy

± (ppm*RD+ppm*RG)

Distortion (%)

100 mA

0.01

300 + 100

<0.5

300 mA

0.01

300 + 100

<0.5

1 A

0.01

300 + 100

<0.5

3 A

0.01

300 + 100

<0.5

10 A

0.01

300 + 100

<0.5

30 A

0.01

300 + 100

<0.5

100 A

0.01

300 + 100

<0.5

250 A

0.01

300 + 100

<0.5

500 A

0.01

300 + 100

<0.5

1000 A

0.01

300 + 100

<0.5

2000 A [1]

0.01

300 + 100

<0.5

Note[3]: Range 2000 A is optional.

• Output range: 10 mA ~ 1020 A (2050 A)

• Frequency: 40 Hz ~ 400 Hz, adjustment fineness 0.001 Hz,accuracy ±0.01%。

• Adjustment fineness: 0.002%*RG

• 6 digits display

• Protections: open-circuit protection, overload protection, over-heat protection


6.3 DC Voltage(optional)

Range

Resolution

Output Range

Max Burden

200 mV

1 μV

20.000 mV ~ 220.000 mV

100 mA

1 V

10 μV

0.10000 V ~ 1.00000 V

100 mA

10 V

100 μV

1.0000 V ~ 11.0000 V

100 mA

30 V

100 μV

3.0000 V ~ 33.0000 V

600 mA

100 V

1 mV

10.000 V ~ 110.000 V

200 mA

300 V

1 mV

30.000 V ~ 330.000 V

60 mA

600 V

1 mV

60.000 V ~ 660.000 V

25 mA

1000 V

10 mV

100.00 V ~ 1100.00 V

20 mA


Range

Stability

(± %/min)

Accuracy

± (ppm*RD+ppm*RG)

Ripple Factor (%)

200 mV

0.01

300 + 200

<0.5

1 V

0.01

300 + 200

< 0.5

10 V

0.01

300 + 200

< 0.5

30 V

0.01

300 + 200

< 0.5

100 V

0.01

300 + 200

< 0.5

300 V

0.01

300 + 200

< 0.5

600 V

0.01

300 + 200

< 0.5

1000 V

0.01

300 + 200

< 0.5

• Output range: 20 mV ~ 1100 V

• Manual or automatic range switch

• Adjustment fineness: 0.002%*RG

• 6 digits display

• Protections: short-circuit protection, overload protection, over-heat protection


6.4 AC Voltage(optional)

Range

Resolution

Output Range

Frequency

Max Burden(rms)

10 V

100 μV

1.0000 V ~ 11.0000 V

40 Hz ~ 400 Hz

800 mA

30 V

100 μV

3.0000 V ~ 33.0000 V

40 Hz ~ 400 Hz

700 mA

100 V

1 mV

10.000 V ~ 110.000 V

40 Hz ~ 400 Hz

200 mA

300 V

1 mV

30.000 V ~ 330.000 V

40 Hz ~ 400 Hz

70 mA

750 V

1 mV

75.000 V ~ 825.000 V

40 Hz ~ 400 Hz

30 mA


Range

Stability

(± %/min)

Accuracy

± (ppm*RD+ppm*RG)

Distortion Factor (%)

10 V

0.01

300 + 200

<0.5

30 V

0.01

300 + 200

<0.5

100 V

0.01

300 + 200

<0.5

300 V

0.01

300 + 200

<0.5

750 V

0.01

300 + 200

<0.5

• Output range: 1 V ~ 825 V

• Frequency: 40 Hz ~ 400 Hz, adjustment fineness 0.001 Hz, accuracy &plusmn;0.01%。

• Manual or automatic range switch

• Adjustment fineness: 0.002%*RG

• 6 digits display

• Protections: short-circuit protection, overload protection, over-heat protection


6.5 DC Resistance(optional)

Range

Resolution

Output Range

Accuracy

± (ppm*RD+ppm*RG)

Allowable Current

100 Ω

1 mΩ

10.000 Ω ~ 110.000 Ω

300 + 200

1 mA ~ 50 mA

1 kΩ

10 mΩ

0.10000 kΩ ~ 1.10000 kΩ

300 + 200

100 μA ~ 5 mA

10 kΩ

100 mΩ

1.0000 kΩ ~ 11.0000 kΩ

300 + 200

10 μA ~ 500 μA

100 kΩ

1 Ω

10.000 kΩ ~ 110.000 kΩ

300 + 200

10 μA ~ 50 μA

1 MΩ

10 Ω

0.10000 MΩ ~ 1.10000 MΩ

300 + 200

1 μA ~ 5 μA

10 MΩ

100 Ω

1.0000 MΩ ~ 11.0000 MΩ

600 + 400

100 nA ~ 500 nA

• Output range: 10 Ω ~ 11 MΩ

• Manual or automatic range switch

• Adjustment fineness: 0.002%*RG

• 6 digits display


6.6 AC\DC Power(optional)

Type

Current Range

Combination of Voltage and Current

Accuracy

± (%*Power Output)[1] [2]

DC

1000 A

(20 mV~1100 V) ×

(10 mA~1050 A)

0.07~0.29

2000 A [3]

(20 mV~1100 V) ×

(10 mA~2100 A)

0.07~0.29

AC

1000 A

(1 V~825 V) ×

(10 mA~1020 A)

0.07~0.42

2000 A[3]

(1 V~825 V) ×

(10 mA~2050 A)

0.07~0.42

2


6.7 Phase and Power Factor(45 Hz~65 Hz)(optional)

Type

Range

Adjustment fineness

Accuracy[1]

φ

0.000°~359.999°

0.005°

0.1°

λ

-1 … 0 … +1

0.0001

0.30% @ (λ=0.5)

3



7. General Specifications

Power supply

AC (380 ± 38)V,( 50 ± 2 ) Hz

Max Power Consumption

16 kVA @ 1000 A Model,32 kVA @ 2000 A Model

Operating Condition

0°C~40°C,(20%~85%) R·H,non-condensing

Storage Condition

-20°C~70°C,(10%~95%) R·H,non-condensing

Standard Interfaces

RS232×1

Dimensions

Range

Width(W)

Depth(D)

Height(H

Diameter of

the copper ring

Ring 1(Ø1)

Ring 2(Ø2)

1000 A

740 mm

1723 mm

1467 mm

10 mm

19 mm

2000 A

1480 mm

1723 mm

1467 mm

10 mm

27 mm

TUNKIA TD1050 Calibration Device for Clamp Meter



8. Ordering information

TUNKIA TD1050 Calibration Device for Clamp Meter

Function

AC/DC Current Output

( ACI & DCI )

AC/DC Voltage Output

( ACV & DCV )

Resistance Output

(Res)

Power Output

(Power)

TD1050-X

TD1050-X-M


Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap