Welcome To TUNKIA !      Electrical Measurement    Magnetic Measurement
You are here: Home » News » Product News » Energy Meter Type Evaluation 2-TD3710 Energy Meter Constant Magnetic Field Test Device

Energy Meter Type Evaluation 2-TD3710 Energy Meter Constant Magnetic Field Test Device

Views: 0     Author: Site Editor     Publish Time: 2024-07-24      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

TUNKIA Energy Meter Type Evaluation 2-TD3710 Energy Meter Constant Magnetic Field Test Device

TD3710-E Electromagnet version

TD3710-P Permanent magnet version

* Reference only. Configuration and details may vary depending on the application scenario.


1. TD3710 Energy Meter Constant Magnetic Field Test Device


TD3710 is a device specially used to test the influence of constant magnetic field on energy meter, which consists of constant magnetic field generating device, DUT test bench, energy meter verification device, calibration interface platform, computer and automatic test software, etc.

The device can be in the form of electromagnet or permanent magnet, which can generate constant magnetic field quantitatively, and cooperate with energy meter verification device to complete the influence test of constant magnetic field on electric energy meter error.


2. Features


Electromagnet (optional): Excited by a precision DC source, a programmable constant magnetic field of 2 mT to 300 mT is generated at the center of the magnetic field generator. The magnetic field distribution generated by the magnetic field generator is similar to the magnetic field of a 50 mm x 50 mm permanent magnet.

Permanent magnet (optional): Equipped with a 50 mm x 50 mm permanent magnet, which can generate 200 mT and 300 mT constant magnetic fields respectively, and equipped with a special magnetic shielding box for placing the permanent magnet after the test.

The system has a built-in high-precision Tesla meter as a magnetic field measurement standard, with a measurement uncertainty of up to 2.0%.

The six sides of the energy meter under test can be tested separately, and the electric energy error of the meter under test can be given.

The system is equipped with computer testing software, which can complete the magnetic field influence test of the energy meter under different magnetic field sizes.

The software has complete data management and backup functions, can output certificates and reports, and supports custom templates.


3. Appearance


☆ TD3710-E Electromagnet Version

TUNKIA Energy Meter Type Evaluation 2-TD3710 Energy Meter Constant Magnetic Field Test Device

S/N

Description

Excitation coil, which can generate a programmable constant magnetic field of 2 mT to 300 mT.

Energy meter tray, which places the energy meter close to the magnetic field source.

Three-phase energy meter voltage and current terminal blocks.

Constant magnetic field excitation power supply and three-phase energy standard device.

Measurement station, which can control the magnetic field and the output of the energy device, so that users can test manually.

Computer (optional) and energy meter automatic test software


☆ TD3710-P Permanent Magnetic Version

TUNKIA Energy Meter Type Evaluation 2-TD3710 Energy Meter Constant Magnetic Field Test Device

S/N

Description

Voltage and current terminals of three-phase energy meter.

Test bench, when conducting DC magnetic field test on energy meter, the DUT is placed in the center of the test bench.

Permanent magnet, applies DC magnetic field to the meter under test placed on the electric energy meter test bench.

Position knob, turning the knob to control the distance between the permanent magnet and the energy meter test bench.

Standard power source of three-phase energy meter calibration device

Measurement station, which can control the output of energy device, so that users can test manually.

Computer (optional) and energy meter automatic test software


4. Specification


Electromagnet-Magnetic Field Index

DC magnetic field range

2 mT ~ 300 mT

Adjustment fineness

1 mT

Magnetic field stability

0.05%/min

Magnetic field measurement range

0 ~ 2 T

Magnetic field measurement uncertainty (k=2)

2.0%

Permanent Magnet-Magnetic Field Index

Magnetic field size

200 mT, 300 mT

Magnet size

50 mm x 50 mm x 50 mm

Central magnetic field accuracy

±10%

Class 0.05 Three-phase Energy Meter Calibration Device

Voltage output range

30 V ~ 456 V

Current output range

5 mA ~ 120 A

Frequency range

45 Hz ~ 65 Hz

Power source stability

0.02% / 2min

Power/electrical energy accuracy

Class 0.05


5. General Specification

Power Supply

Single-phase AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz

Warm-up Time

30mins

Temperature Performance

Working temperature: 5°C~45°C;

Storage temperature: -10°C~55°C

Humidity Performance

Working humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C

Storage humidity: (20%~80%) R H, no condensation

Altitude

< 3000 m

Communication Interface

RS232

Device Size

(including computer desk)

Electromagnet version: 1800 mm (W) x 800 mm (D) x 1400 mm (H)

Permanent magnet version: 1700 mm (W) x 800 mm (D) x 1200 mm (H)


6. Ordering Information

TUNKIA Energy Meter Type Evaluation 2-TD3710 Energy Meter Constant Magnetic Field Test Device


SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap